April 13, 2009
115-V 20-Amp 60-Hz Self-Timed Unit
59
MICRO SWITCH ADJUSTMENT PROCEDURE
Depress the Lid on the top of the unit and listen for the faint click (activation) of the Micro Switch. If the Micro
Switch does not activate or if it activates before the Lid is ¼-inch from being fully depressed, there is probably
a problem with the alignment of the Micro Switch. The following procedure will solve the alignment problem.
Please consult the illustration (Page 58) showing the back of the SUITMATE
®
unit to identify the parts that you
will need to recognize.
REMOVE SUITMATE
®
UNIT FROM THE WALL MOUNT BRACKET
1) Turn off the main electrical power to the unit – place a lockout tag on the circuit breaker panel indicating that
the breaker is not to be turned on except by authorized personnel and disconnect the unit before doing any
work on the SUITMATE
®
unit. Simply turning off a switch is NOT enough.
2) Remove the SUITMATE
®
unit from its Wall Mounting. See instructions beginning on Page 17.
3) Place the unit on its front side and remove the Micro Switch Box Cover to expose the Micro Switch and
Riser Cable Assembly by unscrewing the (2) Machine Screws. Place the screws aside for reassembly later.
NOTE:
Older units may have rivets instead of screws.
CAUTION!
Make certain the main electrical power to the unit is turned off – and locked out
– before beginning work on the SUITMATE
®
unit.
CHECKING MICRO SWITCH ALIGNMENT
1) Stand the unit upright and reaching from the rear push the Lid down on the top of the unit to determine if the
Riser Cable that runs from the top of the unit to the Micro Switch arm is pulling on the arm. If there is no
movement, the Actuator Screw in the top may be broken and will need to be replaced. See the Lid Assembly
section on Page 23 of this manual.
2) If the Cable does pull up on the Micro Switch arm, then the alignment can be adjusted. First, push the Lid
down; the Micro Switch should NOT activate (click) until the Lid is approximately ¼ inch from being totally
depressed. Adjust the alignment by tightening (clockwise will activate unit sooner) or loosening (counter
clockwise will activate later) the Turnbuckle Nut on the bottom of the Riser Cable until the proper adjustment
is obtained. Provide power to the unit and make certain that it is functioning properly.
3) Disconnect the power to the unit.
4) Replace the Micro Switch Box Cover using the (2) Machine Screws removed in step 3.
REATTACH THE SUITMATE
®
UNIT TO WALL
1) Reinstall the SUITMATE
®
unit to the Wall Mount Bracket. See instructions beginning on Page 18.
2) Turn on the main electrical power to the unit and retest to assure proper operation. Refer to TESTING
AND OPERATION on Page 8.
If you have further difficulities or want additional information, please contact Extractor Corporation at:
(Telephone) 800-553-3353, (Fax) 847-742-3552 or (E-Mail) info@suitmate.com and explain your problem.
WWW.RESTROOMDIRECT.COM 704•937•2673 129 Oakpark Dr., Unit A, Mooresville, NC 28115
Содержание Swimsuit Water Extractor
Страница 1: ...115V 60Hz Manual WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Страница 2: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Страница 70: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Страница 71: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Страница 72: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...