April 13, 2009
115-V 20-Amp 60-Hz Self-Timed Unit
17
MECHANICAL ASSEMBLIES
115-V 20-Amp 60-Hz Self-Timed Unit
Note:
Always turn off the power at the circuit breaker – place a lockout tag on the circuit breaker panel
indicating that the breaker is not to be turned on except by authorized personnel – and disconnect the electrical
connections before doing any work on the SUITMATE
®
unit. Simply turning off a switch is NOT enough.
Use only proper tools, test equipment, and work practices when servicing the SUITMATE
®
unit.
If there are questions concerning proper tools, equipment or practices, please call the factory for
recommendations at: (Telephone) 800-553-3353, (Fax) 847-742-3552 or (Email) [email protected].
Due to critical tolerances, use only specified replacement parts. (See the individual sections in this manual.)
Some disassembly and assembly procedures have not been included, as the procedures seem to
be self-evident.
REMOVE SUITMATE
®
UNIT FROM THE WALL MOUNT BRACKET
Do This FIRST
prior to performing any electrical or mechanical maintenance.
• Turn off the main electrical power to the unit – place a lockout tag on the circuit breaker panel indicating that
the breaker is not to be turned on except by authorized personnel – and disconnect the unit before doing any
work on the SUITMATE
®
unit. Simply turning off a switch is NOT enough.
• Consult the individual sections in this manual to determine the exact parts and fasteners that will be required
for installation of mechanical components.
CAUTION!
Make certain the main electrical power to the unit is turned off – and locked out
– before beginning work on the SUITMATE
®
unit.
EXTERNAL ELECTRICAL SERVICE
If the unit’s electrical service is coming into the unit from outside the unit, it will be necessary to disconnect the
incoming electrical service from the power source. Prior to disconnecting the electrical service make certain
that the power source is turned off and locked out! Disconnect the incoming liquid tight raceway or cable from
the power source.
EXTERNAL PLUMBING SERVICE
If the unit’s plumbing service uses the factory supplied Drain Hose or is connected from outside the unit, it will
be necessary to disconnect the drain hose or piping from its external hookup.
INTERNAL ELECTRICAL AND PLUMBING SERVICE
If the SUITMATE
®
unit was installed with internally connected plumbing and electrical connections:
1) Remove the cover of the weatherproof Junction Box that contains the GFCI; remove the GFCI; disconnect
the external source ground wire and the power feed lines from the GFCI terminals marked “Line”. Retain the
weatherproof Junction Box cover and fasteners for reinstallation.
2) Disconnect the power feed liquid tight raceway or cable from the Junction Box and the internally connected
drain hose.
3) Remove the lower fasteners anchoring the unit to the wall.
4) Remove the SUITMATE
®
unit from the Wall Mount Bracket by firmly grasping the sides of the Case bottom
and gently lifting straight up until the unit clears the upper back lip of the Wall Mount Bracket. Take the
SUITMATE
®
unit to a workbench.
WWW.RESTROOMDIRECT.COM 704•937•2673 129 Oakpark Dr., Unit A, Mooresville, NC 28115
Содержание Swimsuit Water Extractor
Страница 1: ...115V 60Hz Manual WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Страница 2: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Страница 70: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Страница 71: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Страница 72: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...