![Suitmate Swimsuit Water Extractor Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/suitmate/swimsuit-water-extractor/swimsuit-water-extractor_installation-and-maintenance-manual_1390102009.webp)
April 13, 2009
115-V 20-Amp 60-Hz Self-Timed Unit
7
Remove the cover of the weatherproof Junction Box, which contains the GFCI, and remove the GFCI
mounting screws. The circuit ground conductor must be connected to the green grounding screw located on
the GFCI. If no ground is available on the circuit utilized, you must provide a proper ground for the SUITMATE
®
unit. The hot and neutral leads of the power circuit should be connected to the GFCI screw terminals marked
“LINE”. Connect the hot lead to the terminal marked “HOT” and the neutral lead to the terminal marked
“NEUTRAL”. After the correct electrical connections have been properly made, remount the GFCI using the
screws previously removed. Reinstall the weatherproof Junction Box cover previously removed. This cover
provides access to the GFCI “TEST” and “RESET” buttons.
POSTING THE WALL SIGN
Locate the top edge of the sign 60+/- 1/16” (1524 +/- 2mm) above the floor centered over the SUITMATE
®
unit.
At this height the sign will not be blocked when the lid is raised. It will also serve as a stop to keep the Lid from
striking the wall behind the unit.
The sign has an adhesive foam backing. Be certain the surface that the sign is to be mounted to is clean and
dry. Without touching the sign to the wall, align the top of the sign 60+/- 1/16” (1524 +/- 2mm) above the floor
and at the center of the unit. Press the sign to the wall and rub firmly over the adhesive portion of the sign.
WARNING!
Do not route the raceway where wastewater can flow or drip on it.
CUSTOMER'S ELECTRICAL SERVICE
115-V / 20-Amp / 60-HZ
WHITE AEC1841 (From Timer To Motor)
GREEN
SCREW
GFCI IS
"GROUND FAULT CIRCUIT INTERRUPTER"
MOTOR CONTROLLER AND SWITCH
BLACK
AEC1840
BLACK
AEC1843
BLACK AEC1842 (From Timer To Motor)
COM
TIMER
N.O.
3
2
HOT NEU GROUND
GREEN
SCREW
HOT WHITE
HOT NEU
LOAD
BLACK
AEC1815
GFCI
WHITE AEC1813
(From GFCI To Motor)
MICROSWITCH
COMMON
GREEN AEC2061
(From GFCI To Motor)
RESET BUTTON, ON
TEST BUTTON, OFF
OPEN
MOTOR
SUITMATE
®
UNIT
L1 L2
WWW.RESTROOMDIRECT.COM 704•937•2673 129 Oakpark Dr., Unit A, Mooresville, NC 28115
Содержание Swimsuit Water Extractor
Страница 1: ...115V 60Hz Manual WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Страница 2: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Страница 70: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Страница 71: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...
Страница 72: ...WWW RESTROOMDIRECT COM 704 937 2673 129 Oakpark Dr Unit A Mooresville NC 28115...