Torque Control Verifier Ethernet 2
2.4GHz FM TCVe2 User Manual
Part Number 857414 Rev A
01 July 2020
Страница 1: ...Torque Control Verifier Ethernet 2 2 4GHz FM TCVe2 User Manual Part Number 857414 Rev A 01 July 2020...
Страница 2: ...9 Click Tool Fields 10 Status Info Group 12 Network Connection Info Group 12 IP Info Group 12 Open Protocol 14 ToolsNet 16 PFCS Setup 18 EtherNet IP 20 Studio 5000 Add On Instructions 20 Connection P...
Страница 3: ...TCV e2 User Manual 3 of 36 P N 857414 Rev A 07 01 2020 Data Management 32 Read Write 32 Barcode Reader 32 Firmware Updates 35 Product Specification 36...
Страница 4: ...hen all four positions have been set press ENT to submit the password An incorrect password entry will display Invalid Password Press ENT Learn is displayed on the screen Press or to change which inte...
Страница 5: ...the power plugs There are no user serviceable parts inside the main enclosure of the unit Unit Overview The TCV e2 is equipped with a main display two segment displays one for each interface navigatio...
Страница 6: ...of tightenings completed in the current batch 2 Batch The number of tightenings required for the current batch 3 Tool Number The number of the tool used 4 Tightening Status The status of the last tig...
Страница 7: ...for use 14 Programming Indicator This decimal point indicates the controller is trying to program the tool NOTE Interface 2 status indicators operate in the same manner as the Interface 1 status indi...
Страница 8: ...current tool for use o Press ENT With Select displayed on the screen press ENT again to activate the tool Forget removes the tool from the unit o Press ENT o Press ENT again to confirm deleting the t...
Страница 9: ...well Time Default 5 0 Range 0 0 to 25 5 seconds Available Modes all This setting controls the amount of time permitted for reseating the tool or ratcheting Head Length Default 36 50 mm Values 0 to 100...
Страница 10: ...Available Modes TAM This setting controls the minimum required angle for a valid tightening This value must be less than Max Ang Max Angle Default 0 Range 0 to 9999 Available Modes TAM This setting c...
Страница 11: ...TBB Time between batches Default 0 Range 0 to 9999 seconds This setting controls the minimum amount of time after a batch completion before another tightening should be accepted Any additional tighten...
Страница 12: ...ch provides additional options The MAC address is assigned by the factory and cannot be changed Changes to these settings only apply after the qualifier is restarted The settings in this page apply to...
Страница 13: ...7414 Rev A 07 01 2020 Reset Defaults Default All Range All Configuration Jobs Tools Events The Reset Defaults screen allows you to restore the unit to the factory defaults You may select some or all p...
Страница 14: ...ACOP connection is considered broken and will have to be re established This will terminate all subscriptions that were established on that connection regardless of which one did not receive a respons...
Страница 15: ...rameter Reset Batch 0038 Job Select 0039 Job Restart 0042 Tool Disable 0043 Tool Enable 0050 VIN Download 0082 Write Time 0127 Job Abort 0130 Job Off 0150 Multi ID Download 0156 Reset Latest Identifie...
Страница 16: ...otocols supported by the qualifier ToolsNet requires the controller to establish connections Since the qualifier will repeatedly make network requests to attempt to establish network connections to th...
Страница 17: ...This setting controls the system number the qualifier reports to the ToolsNet server in identification and tightening packets Each interface may be assigned its own System number Station Number Defaul...
Страница 18: ...nsol Default Disabled Int 1 Sol Auto Default Yes Int 1 Sol Name Default Int 1 Single ID Default Yes Int 1 Unsol Auto Default Yes Int 1 Unsol Name Default Int 1 Sol Port Default 16101 Int 1 Unsol Port...
Страница 19: ...e PFCS connection is considered broken and will have to be re established Retries Range 0 to 10 Default 3 This setting controls how many times the qualifier will resend a tightening or keep alive pack...
Страница 20: ...Connection Points The following connection points are used by the TCVe2 to take input data from the network These connection points allow you to control the running operation of the qualifier 563 Nam...
Страница 21: ...his section defines the connection points are used by TCVe2 to send output data to the network 51x 52x Last tightening data 53x Current qualifier status Input Connection Points for Last Tightening Dat...
Страница 22: ...atch in the parameter Torque Unit INT Unit used for torque fields Torque REAL Torque of the tightening just performed Min Torque REAL Minimum torque required for a tightening in the parameter Max Torq...
Страница 23: ...ID DINT ID number of the last tightening performed by the parameter Total size 40 bytes 532 Name Data Type Description ARRAY of STRUCT of Current status for each of the 2 interfaces Each array entry c...
Страница 24: ...ver EtherNet IP with EDS file and add on instructions of the TCVe2 Importing the EDS file For the first project using a TCVe2 on a given developer machine you will need to import the EDS file into Stu...
Страница 25: ...Manual 25 of 36 P N 857414 Rev A 07 01 2020 3 Select the EDS file to load by browsing to the location where you saved the file and selecting the TCVe2 eds file 4 The file should be parsed successfully...
Страница 26: ...e2 User Manual 26 of 36 P N 857414 Rev A 07 01 2020 5 Ensure that the TCVe2 device is shown on the next screen and Press Next 6 Follow the remainder of the on screen prompts to complete the installat...
Страница 27: ...N 857414 Rev A 07 01 2020 Project Setup In each project you will need to create and Ethernet module for the TCVe2 configure it and add logic to handle the data 1 Create a new Ethernet module 2 Select...
Страница 28: ...Ve2 There are four different connections a Last Tightening Control no VIN b Last Tightening Control with VIN c Current Status Control no VIN d Current Status Control with VIN 5 Import the add on instr...
Страница 29: ...enting the parsed data in the EtherNet IP assembly instance Use these structures to create tags for the input and output data You will need to create an instance of the processing structure and 2 inst...
Страница 30: ...tputs Item Value Unit Dry Contact Voltage 24 VDC Current each 2 A Wet Contact Voltage 24 VDC fixed Current each 2 A Current total 2 A fixed Common Points All inputs share a single common which is tied...
Страница 31: ...u will need to use the Global Manager PC software application I O Label I O Function Opto Input 1 Suspend Interface 1 Opto Input 2 Batch Reset Interface 1 Opto Input 3 Suspend Interface 2 Opto Input 4...
Страница 32: ...ools parameters jobs qualifier and network settings and I O settings This file can be loaded into the PC application for viewing or editing Network Log The network log file will be saved to the USB dr...
Страница 33: ...the VIN or Identifier part 1 VIN characters 1 25 reported by the unit in tightening result messages the ACOP MID 0052 Vehicle ID Number and the ACOP MID 0152 Multiple identifier and result parts notif...
Страница 34: ...ucts the unit to start a parameter Any other running parameter or job will be stopped before starting the new parameter Data number of up to 3 digits specifying the parameter number to select 1 100 Ex...
Страница 35: ...ve contact support If the update was emailed to you you may also try another USB drive 5 Press ENT When the unit changes to the Finding Files screen it will search the root folder of the drive for the...
Страница 36: ...ty 100 dBm 1 packet error FCC Part 15 247 OUR XBEEPRO Industry Canada 4214A XBEEPRO Europe CE ETSI FCC Statement Contains FCC ID OUR XBEE OUR XBEEPRO The enclosed device complies with Part 15 of the F...