8) Compare the results to the actual applied torque obtained from the joint.
a) If the results agree with the actual output of the tool on the joint, record the
information on the joint simulator washer configuration and filter used for this test
for future use with this tool. Testing complete.
b) If the results do not agree with the actual output of the tool on the joint, and all fil-
ters have not yet been tried, another filter may be better to use with this combination
of tool and joint. Go to step 9.
c) If the results do not agree with the actual output of the tool on the joint, and all five
filters have been tried, then an adjustment to the joint simulator will be needed.
i) Use the Power Switch to turn off the tester.
ii) Remove the joint simulator from the tester.
iii) Use the instructions found in Chapter 4 to make the joint simulator emu
late a slightly harder or softer joint.
iv) Return to Step 3 of this procedure.
9) If the test results do not match the tool output, and all four filters have not yet been
tried, it may be that the joint simulator is correct but a different filter may be needed.
a) Press the Filter button on the
Torq-Tronics
®
tester to change to the next filter.
b) Repeat steps 6, 7, and 8 of this procedure.