6) If you want the test results cleared from the LCD after a few seconds, Press the Auto
key once. Activating the Auto function will also send the data to the computer or print-
er if you are using one. If you wish to hold the test results until you clear them,
simply do not press the Auto key.
Test the Tool
1) Engage the hex drive with the power tool. Make certain the tool is held in-line with the
hex drive throughout the test.
2) Trigger the tool until it clutches or stalls, then release the trigger. Since tools in this
size range do not use a joint simulator, the clutch slip or stall will occur very quickly.
The trigger should be released immediately after this occurs. Disengage the tool
from the transducer.
3) Read the torque result on the LCD. The torque result will be displayed moments
after the trigger is released.
4) Evaluate the test result. If the test result closely mirrors the torque wrench result, the
"0" filter is the correct one for this tool, and can be used for testing this tool from
now on. If the test result does not closely mirror the torque wrench result, the cor
rect filter must be found.
a) Press the Peak Select once to page from filter "0" to filter "1".
b) Repeat the first four steps of "Test the tool" above.
c) Evaluate the test results for filter "1".
d) Repeat test/evaluate cycle until the correct filter has been determined.
e) If none of the four filters provides a result matching that of the torque wrench, there
is likely an error in the joint data. Return to this step and gather data for comparison
to measurements taken from each filter.
5) Once correct filter has been determined, record the filter number for future use with
this tool.
Содержание 10191
Страница 2: ......
Страница 6: ......
Страница 8: ...This page intentionally left blank...
Страница 12: ...This page intentionally left blank...
Страница 34: ...This page intentionally left blank...
Страница 40: ...This page intentionally left blank...
Страница 46: ...This page intentionally left blank...
Страница 51: ......