Computer Communications (Optional)
If you will be using your
Torq-Tronics
® with a computer and TTM software or a serial
printer, this is the time to establish communications.
1. Gently insert the male end of your 9-pin serial cable into the serial port on the right side
of your
Torq-Tronics
® unit.
2. Thread the externally-threaded fasteners on either side of the cable terminal into the
internally-threaded securing nuts on either side of the serial port. Tighten fasteners just
enough to secure cable terminus in position.
3. Install the other end of the serial cable to the serial port on your computer or serial print-
er.
4. Serial communications parameters are: 4800 baud, No parity, 8-bit, 1 stop bit.
Test Installation
The last step in the installation process is checking to insure the unit works as installed.
1. Testing Electrical Power Supply
a. Move the power switch to the on position. If the batteries are properly installed and
AC power is connected, the backlit LCD display will come on, a series of messages
will be displayed, and the unit will finish in Track mode at zero torque value in
English units of measurement. If the backlights on the LCD are not lit, it means the
unit is not properly connected to an AC power source. Check power to the AC out-
let, that the charger is firmly plugged into the outlet, and that the charger pin is
fully-inserted into its' receptacle in the
Torq-Tronics
® unit.
b. Unplug the charger from the 120VAC outlet. If the backlight on the LCD goes out
but the characters remain displayed, the batteries have been properly installed. If the
backlight goes out and the characters do not remain displayed, the batteries have
either not been installed or have been improperly installed. To correct this, move the
power switch to the off position, remove the battery pack cover, remove and proper-
ly reinstall the batteries, then reinstall the battery pack. Move the power switch to
the on position and the characters will be displayed.
c. Move the power switch to the off position and reconnect the charger to the 120 VAC
power outlet.
2. Testing communications (Optional)
a. Computer Communications Test
i. Activate terminal software.
ii. Move the power switch on the
Torq-Tronics
® to the on position.
iii. The message "Sturtevant Richmont" then "System 7 Ver 1.1" then
"TORQTRONICS [Model]" will appear in the terminal software window if the
Torq-Tronics is properly connected and the proper serial port is selected and
properly configured. If these letters do not appear, check for proper cable con-
nection, proper port selection, and proper port configuration. Serial communica-
tions specifications may be found in the Specifications section of this manual.
Содержание 10191
Страница 2: ......
Страница 6: ......
Страница 8: ...This page intentionally left blank...
Страница 12: ...This page intentionally left blank...
Страница 34: ...This page intentionally left blank...
Страница 40: ...This page intentionally left blank...
Страница 46: ...This page intentionally left blank...
Страница 51: ......