Preparing the Torque Wrench
Check that the torque wrench to be tested is of equal or lesser torque capacity than the
tester. Under no circumstances should the
Torq-Tronics
®
be used beyond its' rated capaci-
ty! Adjust the torque wrench to the desired torque level for testing.
If your
Torq-Tronics
®
has a male hex drive, put a socket of the same size on the front of
the torque wrench, so the transducer drive can be engaged by the tool. If your
Torq-
Tronics
®
has a female square drive, a torque wrench square drive can be inserted directly
into a transducer square drive. If the square drives are of different sizes, use a square drive
adapter to mate the tool and transducer. Always use as few adapters as possible; the more
the torque wrench stands out from the transducer, the more likely error may be induced.
Testing the torque wrench.
Grasp the torque wrench at its' load point, and apply slowly increasing force steadily until it
clicks. Stop applying force immediately, and allow the torque wrench to reset. The meas-
urement will be displayed on the LCD.