Stratasys Document Number 206465-0001
Troubleshooting and Maintenance
63
D. Select
Increment
or
Decrement
to input the X offset adjustment - the value will change in the
upper display window (by default, the printer will be ready to accept the X value).
E. When you are satisfied with your X offset value,
Select Y
and repeat steps A- D to identify and
input the required Y Tip Offset adjustment.
5. Select
Done
after you have input the X and Y offsets. The printer will return to
Maintenance
. Run the
XY calibration a second time to be sure the values changed the offset properly.
Figure 43: Example XY Tip Offset Part.
This example requires an adjustment of X = + 2 mils, Y = - 4 mils
Remove Debris Buildup
Remove all material buildup on the Z Platform and around the lead screw. Failure to do so could cause the
base to not be level or the Z Platform to jam at its upper limit.
Vacuum Build Chamber
Vacuum the build chamber to remove all debris and purged material.
Clean Door
Do not use glass cleaner on the door. It will damage the acrylic window.
CAUTION
ONLY use acrylic cleaner.
Содержание 180-00108 uPrint