Stratasys Document Number 206465-0001
Troubleshooting and Maintenance
52
Figure 31: Create access space for cleaning - model side shown
5. Move the toggle bar to ‘deactivate’ the clogged tip.
Note:
Push the toggle bar to the right to deactivate the support side.
Push the toggle bar to the left to deactivate the model side.
6. Snip the material just after the it passes between the material drive and the idler wheel (‘pinch point’).
Note:
If necessary manually pull more material forward in order to reach
the ‘pinch point’.
7. Move the toggle bar to activate the clogged side. This will make the drive wheel control options active
for the clogged side.
Note:
Push the toggle bar to the left to activate the support side; push
the toggle bar to the right to activate the model side.
8. Press
Forward
on the interface panel. The drive wheel will turn, but material will not feed because the
idler wheel is held out of position.
9. Use the 7/64 T-Handle to hold pressure against the toggle spring and keep the idler wheel away from
the material. Remove the 1/8 T-Handle.
10. Press
Blower Off
on the interface panel. With the head blower off the temperature of the extrusion
tube will increase.