Stratasys Document Number 206465-0001
Operation
40
Removing a completed part
When the printer has completed building a part, the display will show
Completed
followed by the file
name. It will also show
Remove Part
and
Replace Modeling Base
.
Remove a completed part from the printer:
1. Open the chamber door.
2. Turn the modeling base retainers down and remove the modeling base by sliding out and pulling up.
3. Insert a new modeling base by sliding in and pushing down, turn the retainers up to lock the modeling
base in place.
4. Close the chamber door.
5. After you have opened and closed the door, the display will show
Part Removed?
ONLY
after remov-
ing the part and replacing the modeling base, from the display panel press
Yes
.
•
After you press
Yes
, the display will show the status as
Idle
or
Ready to Build
for the next part in
the queue.
Remove a part from the modeling base:
1. After removing the modeling base from the printer, firmly flex the modeling base back and forth with
your hands to loosen the part.
2. Pull the part off of the modeling base or use a putty knife to completely remove the part.
Note:
Parts are easier to remove from the modeling base when it is still
warm.
CAUTION
The modeling base will be hot, wear gloves when removing the part from the
printer.
CAUTION
If you press
Yes
before removing the part, the printer can be damaged.
Содержание 180-00108 uPrint
Страница 1: ...User Guide ...