Telephone Button Programming
900 Series Programs
Strata CIX Programming Vol.1 12/09
13-5
T
e
lepho
ne Butt
on
Progra
mming
900 Series Programs
These programs are organized based on functions versus program numbers.
System Initialize
This program enables you to reset hardware and initializes, or restores, programmed data.
Program Number(s): 900
Prerequisite Program:
None
Reference:
None
Access Sequence:
Login to programming mode from your telephone button pad:
Hold Q#Q#1Q2Q3Q
.
At the
PASSWORD=
prompt, enter your password and press
Hold
.
At the
PROG=
prompt enter
900
and press
Hold
.
To access programming parameters
1. Press
FB01
to choose Initialize Level 1 or 2.
2. Press
Hold
twice to initialize.
Important!
Choosing Initialize Level 1 without installing a SmartMedia Card deletes all programmed
data and returns your Strata CIX to factory default settings. All previously programmed data
is lost.
Restoring Data from SmartMedia
When initializing with Level 1 you can restore custom data that was previously programmed and stored on
a SmartMedia card. To do so, follow the steps below.
1. Install a SmartMedia card that contains the Prog data directory with the default.dat file. The default.dat
file contains your custom settings and can be created by running Data Backup. See Data Backup.
Important!
A CIX/CTX default.dat database can only be restored to a CIX/CTX software version that is
the same or higher than the CIX/CTX software version on which the default.dat file was
created. For example, a default.dat created on CTXR2.0 MF029 can be restored on an R2.0
MF030, MF031 and higher R2.1MG0XX, R2.2 MF0XX (XX = 01~99, but it cannot be
restored on R2.0 MF012, MF011 and lower, or R1.X ME0XX, MD0XX, etc.
2. After installing the SmartMedia card, run System Initialization using Initialize Level 1.
Restoring data from the SmartMedia card may take an hour or more. To verify completion of the restore
process access, the Programming Mode from a telephone and enter your password. If the system
enables you to continue, the data restore process is complete.
Note
During the restore process the telephone LCD may display date and time data. This does not
necessarily indicate completion of the restore process.
FB Name
FB
Summary
Value
LCD Prompt
Initialize Level
01
Press
1
or
2
to select the initialize level.
Level 1 – Erases programmed data and
enters default data or backed up data if a
SmartMedia Card is installed (see Note).
Level 2 – Simulates System Power Off/Power
On operation to reset hardware.
1.
Initialize Level 1
2.
Initialize Level 2
1:Restart with
Clear Data
2:Restart
Содержание CIX 200
Страница 42: ...Network eManager 2 4 Strata CIX Programming Vol 1 12 09 ...
Страница 43: ...Network eManager Strata CIX Programming Vol 1 12 09 2 5 Network eManager ...
Страница 44: ...Network eManager 2 6 Strata CIX Programming Vol 1 12 09 ...
Страница 314: ...This page is intentionally left blank ...
Страница 432: ...This page is intentionally left blank ...
Страница 434: ...This page is intentionally left blank ...
Страница 468: ...This page is intentionally left blank ...
Страница 508: ...THIS IS THE LAST PAGE OF THE DOCUMENT ...