Operation
Alarm Control
Strata CIX Programming Vol.1 12/09
10-17
Oper
ation
Alarm Control
System Availability: Not available with CTX28
Program Number(s): 919 and 920
Alarm Notification (AN) sends a notification of a system alarm condition. The notification can be sent over
a network connection to an eMonitor system, other application and, optionally, to a feature button on a
telephone. The alarm notification is SNMP trap data that can be sent to as many as 11 different IP
addresses. Up to eight stations can have a button programmed as an Alarm Indicator. There are three
categories of alarms: ISDN, T1, and System Resources.
There are two types of SNMP messages sent to the external, eMonitor, PC or Server; (1) Alarm
Notification when an error condition occurs. (2) Current Alarm Condition Summary sent every 10 minutes
whether an alarm has occurred or not.
The following programs enable you to control the alarm settings for a system or slot(s) for Network
eManager users.
System Alarm Control (Program 919)
Select Alarm/Traffic > Alarm Setup > System Alarm.
Prerequisite Program:
None
This program resets all alarms and enables/disables the Current Alarm Summary notification.
F
IELD
D
ESCRIPTION
01 Clear Alarm
Buffer
The Clear command resets all current alarms. This command is used to
manually clear the buffer. Set to Invoke and Submit to clear the buffer.
When the clear command is invoked the system will not re-send a
persisting T1 or PRI alarm condition.
When an alarm condition is clear for several seconds, the system will clear
the buffer without the need to manually clear the buffer.
Possible values:Idle, Invoke (default = idle)
02 Alarm Buffer
Status
This command when enabled sends the alarm status to the Alarm Monitor
device periodically (approx. 10 minutes).
Possible values:Enable/Disable.
System ID
This number is sent in the SNMP Alarm Trap data stream to the CIX Alarm
Monitor application, or any other SNMP trap monitor. It can be used as the
System ID of a CIX node or the same System ID can be assigned to
multiple nodes to identify a group of systems (max. 8-characters, alpha-
numeric).
Содержание CIX 200
Страница 42: ...Network eManager 2 4 Strata CIX Programming Vol 1 12 09 ...
Страница 43: ...Network eManager Strata CIX Programming Vol 1 12 09 2 5 Network eManager ...
Страница 44: ...Network eManager 2 6 Strata CIX Programming Vol 1 12 09 ...
Страница 314: ...This page is intentionally left blank ...
Страница 432: ...This page is intentionally left blank ...
Страница 434: ...This page is intentionally left blank ...
Страница 468: ...This page is intentionally left blank ...
Страница 508: ...THIS IS THE LAST PAGE OF THE DOCUMENT ...