Applications Guide
Network Busy Lamp Field (BLF)
A-18
Strata CIX Programming Vol.1 12/09
•
03 Data Flow = Asynchronization
•
04 Server Port No. = 3000
•
05 Client IP 1-4 No. = Default
•
06 Client Port No. = Default
•
07 Read Retry No. = 1
•
08 Write Retry No. = 1
•
09 CallerName Set To CSTA = No
6. Make sure the Remote Node IP address and Network DSS port Number are consistent. Select Strata
Net > Remote Node IPU Address (Program 674).
7. In Program 670, enter the parameters as follows:
•
field 00 - Remote Node ID = 17. (This is a Strata Net Node ID. In the example above these Node IDs
are 16, 17 and 18.
•
field 01 - Remote Node IP Address = IP address of the remote CIX. Using Node 17 in this example, the
IP address is 192.168.1.43.
•
field 02 - Remote Node Port No. = 3000. This port number is the Network DSS port number. The
Network DSS port number can be any available port. All Network DSS ports should also be the same,
i.e; 3000 in the above example.
8. Verify the DSS refresh time in System > System Timer, field 23 – Network DSS Refresh Timer. Refer to
9. Assign the DSS Remote Node feature key using Station > Station Assignments. Refer to
. DSS button can have up to seven digits, so Node ID can be included. Before
R1.3 five digits were the maximum allowed in a DSS button.
10. From each remote CIX, repeat steps 1~9 to set up Network DSS.
Содержание CIX 200
Страница 42: ...Network eManager 2 4 Strata CIX Programming Vol 1 12 09 ...
Страница 43: ...Network eManager Strata CIX Programming Vol 1 12 09 2 5 Network eManager ...
Страница 44: ...Network eManager 2 6 Strata CIX Programming Vol 1 12 09 ...
Страница 314: ...This page is intentionally left blank ...
Страница 432: ...This page is intentionally left blank ...
Страница 434: ...This page is intentionally left blank ...
Страница 468: ...This page is intentionally left blank ...
Страница 508: ...THIS IS THE LAST PAGE OF THE DOCUMENT ...