Data Backup and Restore
Local Update
Strata CIX Programming Vol.1 12/09
14-11
CAUTION!
This operation will take the system out of service for 10 minutes to an hour or more
depending on the CIX database. Do not skip any steps or the Update will fail.
Notes
•
If CLRREBOOT is activated without the Backup data SmartMedia card installed, the active and
standby software is swapped and the system default program data is restored.
•
The Strata CIX processor heartbeat LED stops flashing and all telephones become inactive. After
a few minutes the Strata CIX initializes and starts up with new version of software as active and the
original software as standby, and then restores the backed up program data from the SmartMedia
card default.dat file (the processor SmartMedia LED flashes while it restores the program data to
the processor RAM).
•
After CLRREBOOT has completed the new version of CIX System software will be active in Trial
mode.
•
If system power is turned off/on while the Active side of flash memory is in the Trial mode, the
original software switches back to active and the new software will switch back to Standby. This is
to provide an automatic method of switching back to the original software version if the new
version is causing problems.
7.
Confirm that the software is updated and the Backup data is restored by verifying/doing the following:
•
Make sure the processor SmartMedia LED is off.
•
Log in to programming mode from a digital telephone. If you cannot log in, it means the data restore
process is not completed.
•
From the programming telephone, in Program 901 make sure that the new Strata CIX system
software version number is on the active side.
FB01
shows the new system software version
number on the active side, and
FB02
shows the original software version number on standby side.
8.
Set the Active side of flash RAM from “Trial” to “Normal” as follows:
•
From the programming telephone, enter Program 911 and press
Hold
. Press
FB04
and dial
1
(NORMAL), then press
Hold
. The new software is on the active side running in Normal mode.
•
If Strata CIX power is turned off/on before the Active side is switched to “Normal”, the Strata CIX will
automatically perform a CLRREBOOT and make the old software active.
Note
The active side switches from “Trial” to “Normal” automatically after 24 hours if it is not done
manually using Program 911.
9.
Remove the SmartMedia card and turn the power off for 5 seconds and then back on to reset BIPU-M,
BIPU-Q, QISG, ISDN and other advanced features.
10. Test the system to verify that the new software is running properly by checking dial tone, making
incoming and outgoing calls, internal and external calls and all other peripherals, such as voice mail,
etc., are working correctly.
11. Toshiba recommends that the SmartMedia card containing the customer data remains installed on the
CIX processor. This enables you to make and backup changes using Network eManager remotely.
Important!
It is your responsibility to verify the system is working correctly after local Update is
complete.
Содержание CIX 200
Страница 42: ...Network eManager 2 4 Strata CIX Programming Vol 1 12 09 ...
Страница 43: ...Network eManager Strata CIX Programming Vol 1 12 09 2 5 Network eManager ...
Страница 44: ...Network eManager 2 6 Strata CIX Programming Vol 1 12 09 ...
Страница 314: ...This page is intentionally left blank ...
Страница 432: ...This page is intentionally left blank ...
Страница 434: ...This page is intentionally left blank ...
Страница 468: ...This page is intentionally left blank ...
Страница 508: ...THIS IS THE LAST PAGE OF THE DOCUMENT ...