Services
External Devices
Strata CIX Programming Vol.1 12/09
9-49
Ser
v
ices
576 Door Phone Night Ring Over External Page
This assignment sets the Page Group that should ring during the system Night Mode when a door phone
button is pressed. The assignment can be made for Tenant 1 only.
02 Tenant Number
Enter the Tenant Number (1~8) for which the door phone should ring over
external page in the system Night mode. All CIX systems provide up to 8
tenants. CTX Release 1.0 only supports Tenant 1).
(default = 1)
04 Ring Duration
Enter the time in seconds that the door phone should ring destination
devices when the door phone button is pressed.
The ring time can be 3 to 30 seconds set in 3 second intervals - each 3
second interval provides one ring to the destination. Destination devices
include selected DNs and page groups.
Possible values: 3~30 (default = 9)
05 LCD Name Display
Enter the door phone name that should display on LCD telephones when
the door phone rings the telephones, or when the telephone calls the door
phone.
Possible values:Up to 16 characters (default = no value)
06 Day1 Destination/
Destination Number
07 Day2 Destination/
Destination Number
08 Night Destination/
Destination Number
Select the type of destination that should ring when the door phone button
is pressed during the system Day1, Day2 or Night mode.
Possible values:None (default), DN or Paging Group 1~4 (CIX100);
1~8 (CIX200, CIX670/1200 Basic); 1~16 (CIX670 Exp),
1~24 (CIX1200 Exp)
Enter the destination number. If the ring destination type is a PDN or
PhDN, enter the directory number. If the ring destination type is page, enter
the page group number.
Possible values:Up to 5 ASCII characters (default = no value)
F
IELD
D
ESCRIPTION
00 Tenant Number
Select the system tenant number to be assigned door phone to page
group/night ringing.
Possible values:1(default)~8
01 Page Group Number
Select the system page group number that should ring for the selected
tenant when a door phone button is pressed during the system night mode.
Possible values:0~4 (CIX100), 0~8 (CIX200, CIX670, C1200 Basic),
0~16 (CIX670 Exp), 0~24 (CIX1200 Exp) (default = 0)
F
IELD
D
ESCRIPTION
Содержание CIX 200
Страница 42: ...Network eManager 2 4 Strata CIX Programming Vol 1 12 09 ...
Страница 43: ...Network eManager Strata CIX Programming Vol 1 12 09 2 5 Network eManager ...
Страница 44: ...Network eManager 2 6 Strata CIX Programming Vol 1 12 09 ...
Страница 314: ...This page is intentionally left blank ...
Страница 432: ...This page is intentionally left blank ...
Страница 434: ...This page is intentionally left blank ...
Страница 468: ...This page is intentionally left blank ...
Страница 508: ...THIS IS THE LAST PAGE OF THE DOCUMENT ...