IMPORTANT:
The green
Signal Strength
LED will pro-
vide a valid reading
only
when the red
Diagnostic
LED is
NOT lit (blinking or solid) and the yellow
Status
LED is not
on solid.
Red Diagnostic LED:
Labeled "
D7
" on the PCB, this LED
will light and flash when the unit is powered (see
OPERA-
TION
, above). One blink indicates a weak or non-existent
signal from the network (green
RF Signal Strength
LED is
off).
Green Power LED:
When lit, the unit is powered on.
Note:
To maximize battery life, press the "
O
" on the side
switch to power off when not in use.
Yellow Status LED:
When the unit is first powered, this
LED will turn on solid for a few seconds, flash, remain on sol-
id again and then turn off. After a connection to the cell tower
is made and the unit is in a normal standby condition, it will
then blink momentarily every 10 seconds.
Red Trouble LED:
This LED will blink as follows:
1 Blink:
Low Aux Power input voltage
2 Blinks:
Battery trouble
3 Blinks:
Alarm report Failed to Communicate
4 Blinks:
RF trouble (antenna connection or cellular
registration)
5 Blinks:
Network trouble (signal unable to reach the
SLE Control Center)
6 Blinks:
Unit disabled (reporting or control panel
WI2346ALF 6/20
R
333 Bayview Avenue, Amityville, New York 11701
For Sales and Repairs, (800) 645-9445
For Technical Service, (800) 645-9440 or visit us at
http://tech.napcosecurity.com/
(Note: Technical Service is for security professionals only)
Publicly traded on NASDAQ Symbol: NSSC
© NAPCO 2020
The StarLink
™
Signal Strength Tester allows you to perform a
site survey test of the premises to find the optimum installa-
tion locations for your StarLink
™
alarm capture communica-
tor. Four different models are available, the
SLE-LTEV-SS
and
SLE-LTEV-SS-CF
(LTE Verizon cellular network);
SLE-LTEA-SS
and
SLE-LTEA-SS-CF
(LTE AT&T cellular
network).
For more information, visit
tech.napcosecurity.com
to down-
load PDF files of all needed documentation.
SPECIFICATIONS
Battery Pack:
Standard USB 5V 10000mAh
Note:
Unit must be off when charging battery.
Battery Life Indicator:
Four (4) small blue LEDs display
the real-time percentage of remaining battery power
(recharge when one LED is lit)
Typical Battery Life:
About 23 hours of continuous use
after a full charge
Battery Charger:
5V/2A wall plug adapter
Dimensions
(W x H x D)
:
8 x 5-
29
/
64
x 1½" (20.3 x 13.9 x
3.8cm)
Operating Temperature:
0° - 49°C (32° - 120°F)
Humidity:
Maximum 93% Non-Condensing
Indoor / dry location use only
OPERATION
1. Power on (press "
–
" on the rocker switch).
2. Wait 1-2 minutes for unit to enter "
Standby Mode
" with
LEDs indicating:
Top Red LED flashes, then turns off
Right Green LED flashes
Yellow LED momentary flashes
3. Place unit in potential installation location.
4. Wait 2 minutes.
5. Count the right Green LED flashes (
acceptable power
level is greater than or equal to 2 blinks
).
If moving location, go to step 4.
If the top Red LED blinks or turns on solid, you MUST
go to step 2. If step 2 LED flashes do not occur, signal
is likely too weak (try a different location).
Power off when not in use and when charging
.
After
powering off, wait at least 30 seconds before power-
ing on.
LED DESCRIPTIONS
There are five (5) LEDs on the front of the unit:
Green RF Signal Strength LED:
Every 30 seconds, the
StarLink communicator receiver turns on and listens to the
cell tower. Depending on the signal strength detected, this
LED will blink from 1 to 5 times at a constant rate (with a
short delay between blink cycles) to provide a signal strength
indicator that is updated constantly and is always displayed.
Acceptable power level is greater than or equal to 2
blinks.
StarLink
™
Communicator
Signal Strength Tester
Operating Instructions
Green
Power
Yellow
Status
Green RF
Signal Strength
Red Trouble
Red Diagnostic
Front LED Descriptions
Signal Strength Tester
SLE-LTEV-SS
POWER INDICATOR
P OWE R OFF WHE N
NOT IN USE
1. P ow e r on (p r es s "
–
" on t h e r oc ke r s wit ch ) .
2. W ai t 1 -2 mi nu te s f or uni t t o e nt er "
St a n db y
M o d e
" w i th LE Ds i n d i ca t i n g:
T op R e d fl as h es , t h e n tu r ns o ff
Rig h t G re e n fl as he s
Yell o w m o me n ta ril y fl as h es
3. Pl ac e u ni t i n p ot e nt ia l i ns t all at io n lo c ati o n.
4. W ai t 2 mi n ut e s.
5. C o un t th e r ig h t Gr e e n Si g n al St re n gt h L ED bl in ks .
T he mi ni m u m ac ce p ta bl e si g na l s t re n gt h is 2 bli nk s.
If m o vi ng l oc at io n, go t o st e p 4 .
If t he t o p Re d L ED bl in ks o r t u rn s o n so li d, y ou MU ST go t o st e p
2. If t h e s t ep 2 LED f la s he s d o n ot o cc u r, si g na l i s lik el y to o
we ak (t ry a dif f er e nt l oc at io n ).
Pow e r o ff w he n n ot i n u se a n d w he n c ha r gi ng .
A ft e r po w erin g o ff ,
wa i t a t le a s t 3 0 s ec o n d s b e f or e p o w eri n g o n.
F or m or e in f or m at io n , se e WI 2 3 46 .
LA
35
52