IMPORTANT: 

 The green 

Signal  Strength 

LED will pro-

vide a valid  reading 

only 

when the  red 

Diagnostic 

LED  is 

NOT lit (blinking or solid) and the yellow 

Status 

LED is not 

on solid.    

 

  Red  Diagnostic  LED:

  Labeled "

D7

" on the PCB, this LED 

will  light  and  flash  when  the  unit  is  powered  (see 

OPERA-

TION

, above).  One blink indicates a weak or non-existent 

signal  from  the  network  (green 

RF  Signal  Strength 

LED  is 

off).   

 

  Green  Power  LED:   

When  lit,  the  unit  is  powered  on.  

Note: 

 To maximize battery life, press the "

O

" on the side 

switch to power off when not in use.  

 

  Yellow  Status  LED:   

When the unit is first powered, this 

LED will turn on solid for a few seconds, flash, remain on sol-

id again and then turn off.  After a connection to the cell tower 

is made and the unit  is  in a normal  standby condition,  it  will 

then blink momentarily every 10 seconds.   

 

  Red Trouble LED:  

This LED will blink as follows: 

 

1 Blink: 

 Low Aux Power input voltage 

 

2 Blinks: 

 Battery trouble 

 

3 Blinks:

  Alarm report Failed to Communicate  

 

4  Blinks:

  RF trouble (antenna connection or cellular 

registration)  

 

5  Blinks:

  Network trouble (signal unable to reach the 

SLE Control Center)  

 

6  Blinks: 

  Unit  disabled  (reporting  or  control  panel 

WI2346ALF  6/20 

R

333 Bayview Avenue, Amityville, New York 11701 

For Sales and Repairs, (800) 645-9445 

For Technical Service, (800) 645-9440 or visit us at 

http://tech.napcosecurity.com/ 

(Note:  Technical Service is for security professionals only)

 

Publicly traded on NASDAQ      Symbol: NSSC 

© NAPCO 2020 

  The StarLink

 Signal Strength Tester allows you to perform a 

site survey test of the premises to  find the optimum  installa-

tion  locations  for  your  StarLink

  alarm  capture  communica-

tor.    Four  different  models  are  available,  the 

SLE-LTEV-SS 

and 

SLE-LTEV-SS-CF 

(LTE  Verizon  cellular  network); 

SLE-LTEA-SS 

and 

SLE-LTEA-SS-CF 

(LTE  AT&T cellular 

network).   

  For  more  information,  visit 

tech.napcosecurity.com

  to  down-

load PDF files of all needed documentation.   

 

SPECIFICATIONS

 

Battery Pack:

  Standard USB 5V 10000mAh 

 

Note:

  Unit must be off when charging battery.   

Battery  Life  Indicator:

  Four (4) small blue LEDs display 

the  real-time  percentage  of  remaining  battery  power 

(recharge when one LED is lit) 

Typical  Battery  Life:

  About 23 hours of continuous use 

after a full charge   

Battery Charger:

  5V/2A wall plug adapter 

Dimensions

  (W x  H x  D)

:

  8 x 5-

29

/

64

  x 1½"  (20.3  x 13.9  x 

3.8cm) 

Operating Temperature:

  0° - 49°C (32° - 120°F)  

Humidity: 

 Maximum 93% Non-Condensing 

Indoor / dry location use only 

 

OPERATION 

1.  Power on (press "

" on the rocker switch). 

2.  Wait 1-2 minutes for unit to enter "

Standby Mode

" with 

LEDs indicating: 

 

Top Red LED flashes, then turns off 

 

Right Green LED flashes 

 

Yellow LED momentary flashes 

3.  Place unit in potential installation location. 

4.  Wait 2 minutes. 

5.  Count the right Green LED flashes (

acceptable power 

level is greater than or equal to 2 blinks

). 

 

If moving location, go to step 4.  

 

If the top Red LED blinks or turns on solid, you MUST 

go to step 2.  If step 2 LED flashes do not occur, signal 

is likely too weak (try a different location).  

Power off when not in use and when charging

.  

After 

powering off, wait at least 30 seconds before power-

ing on.

   

 

LED DESCRIPTIONS 

  There are five (5) LEDs on the front of the unit: 

 

  Green  RF  Signal  Strength  LED:   

Every 30 seconds, the 

StarLink  communicator  receiver  turns  on  and  listens  to  the 

cell  tower.    Depending  on  the  signal  strength  detected,  this 

LED  will  blink  from  1  to  5  times  at  a  constant  rate  (with  a 

short delay between blink cycles) to provide a signal strength 

indicator that is updated constantly and is always displayed.   

 

 

Acceptable  power level  is greater  than or equal  to 2 

blinks.   

 

StarLink

 Communicator 

Signal Strength Tester 

Operating Instructions 

Green  

Power 

Yellow 

Status 

Green RF  

Signal Strength 

Red Trouble 

Red Diagnostic  

Front LED Descriptions 

Signal Strength Tester 

SLE-LTEV-SS

 

POWER INDICATOR  

P OWE R OFF  WHE N 

NOT  IN USE 

1.  P ow e r  on   (p r es s  "

"  on  t h e  r oc ke r  s wit ch ) .  

2.  W ai t  1 -2   mi nu te s  f or   uni t  t o  e nt er   "

St a n db y 

M o d e

"  w i th   LE Ds  i n d i ca t i n g:  

 

T op  R e d  fl as h es , t h e n  tu r ns  o ff  

 

Rig h t  G re e n  fl as he s  

 

Yell o w  m o me n ta ril y  fl as h es  

3.  Pl ac e  u ni t i n  p ot e nt ia l i ns t all at io n  lo c ati o n.  
4.  W ai t  2  mi n ut e s.  
5.  C o un t  th e  r ig h t  Gr e e n Si g n al  St re n gt h  L ED  bl in ks .  
      T he   mi ni m u m  ac ce p ta bl e  si g na l s t re n gt h  is  2   bli nk s.  

 

If  m o vi ng  l oc at io n,   go  t o  st e p  4 .   

 

If  t he  t o p  Re d  L ED  bl in ks  o r  t u rn s  o n  so li d,  y ou   MU ST   go  t o  st e p 
2.    If  t h e s t ep   2  LED  f la s he s  d o  n ot  o cc u r,  si g na l i s  lik el y  to o  

we ak   (t ry  a   dif f er e nt  l oc at io n ).    

Pow e r  o ff  w he n  n ot  i n  u se  a n d  w he n  c ha r gi ng .   

A ft e r  po w erin g  o ff , 

wa i t  a t  le a s t  3 0  s ec o n d s  b e f or e  p o w eri n g   o n.

    

F or   m or e  in f or m at io n ,  se e  WI 2 3 46 .  