Fault diagnosis
Operation & maintenance instructions (Version H)
76
SKY-200/250
Table 8.4
Vehicle lift lowers by itself
Possible cause
Solution
The cylinder seal is damaged. Oil is leaking
continuously.
Have sealings or cylinder replaced by trained
lift service personnel.
Oil line couplings leaking.
Tighten couplings and coupling nuts.
Dirty or damaged non-return valve.
Have oil filter and ball behind it cleaned by
trained lift service personnel.
Clogged or damaged lowering valve (s).
Have valve cleaned or replaced by trained lift
service personnel.
Table 8.5
Vehicle lift does not raise properly
Possible cause
Solution
Oil level in tank too low.
Top up oil according to
; also see the
'Lubricating Instructions' sticker on the
device.
Pump draws in air.
Tighten suction filter fastening or crimp
tighter.
Bleed valve blocked (breather cap).
Clean cap.
Содержание SKY-200
Страница 23: ...Safety Operation maintenance instructions Version H 23 SKY 200 250 2 Figure 2 3 Safety and warning labels ...
Страница 115: ...Figures and diagrams Operation maintenance instructions Version H 115 SKY 200 250 A Figure A 10 2 Control box ...
Страница 130: ...Dimensional drawing Operation maintenance instructions Version H 130 SKY 200 250 Figure A 14 2 Dimensional drawing ...
Страница 131: ...Figures and diagrams Operation maintenance instructions Version H 131 SKY 200 250 A Figure A 14 3 Dimensional drawing ...
Страница 134: ...Track lighting Operation maintenance instructions Version H 134 SKY 200 250 Figure B 1 2 Track lighting ...
Страница 152: ...Operation maintenance instructions Version H 152 SKY 200 250 ...
Страница 153: ......