Assembly
Operation & maintenance instructions (Version H)
41
SKY-200/250
4
4.5.2
Hydraulic, pneumatic and electric connections
1.
Connect the hydraulic hoses and the air hoses (6 mm) the correct way as stated in
. It is important to connect the correct colours, because otherwise the lift
will go into an error state. The air supply to the 2/3 valve has to be between 5 and
8,3 bar and must comply with ISO 8573 class 5 no lubrication. As an option, an air
supply kit can be installed (see chapter
2.
Connect the two pneumatic return hoses (drain from the hydraulic cylinders) to the
dedicated connections on the oil tank (push-in fittings); see
Figure 4.11
Hydraulic connections and air connection