Faults
Operation & maintenance instructions (Version H)
73
SKY-200/250
8
8.5
Fault diagnosis
88 & tt
This is not a fault.
Indicates that the processor is resetting (e.g.
at start-up).
89 through 96
Internal control fault.
Turn mains switch off and on. Alert the
Technical Service if it persists.
98 & 99
Internal control fault.
Turn mains switch off and on. Alert the
Technical Service if it persists.
Table 8.1
Fault codes
Code
Possible fault
Solution
Table 8.2
Vehicle lift does not raise
Cause
Solution
No mains power.
Have fault corrected by authorized
electrician.
Oil level too low.
Top up, see
7.3.1 ’Lubrication instructions’ on
Air in pump (only possible after the tank has
been empty).
Operate the push buttons on the circuit board
inside the control box.
Steadily press buttons MS and M1 up to M4
at the same time for 1 minute.
Pressure relief valve opens because of
overloading.
• Vehicle lift overloaded.
• Pressure relief valve not properly adjusted;
have it adjusted by trained lift service
personnel.
Содержание SKY-200
Страница 23: ...Safety Operation maintenance instructions Version H 23 SKY 200 250 2 Figure 2 3 Safety and warning labels ...
Страница 115: ...Figures and diagrams Operation maintenance instructions Version H 115 SKY 200 250 A Figure A 10 2 Control box ...
Страница 130: ...Dimensional drawing Operation maintenance instructions Version H 130 SKY 200 250 Figure A 14 2 Dimensional drawing ...
Страница 131: ...Figures and diagrams Operation maintenance instructions Version H 131 SKY 200 250 A Figure A 14 3 Dimensional drawing ...
Страница 134: ...Track lighting Operation maintenance instructions Version H 134 SKY 200 250 Figure B 1 2 Track lighting ...
Страница 152: ...Operation maintenance instructions Version H 152 SKY 200 250 ...
Страница 153: ......