background image

 Stamm International Corporation

PO Box 1929

Fort Lee, NJ 07024

Tel: 201-947-1700

Fax: 201-947-9662

 E-mail: [email protected]

Stamm International HQ

w w w . p o w r m a t i c . c o . u k        

w w w . p o w r m a t i c . c o . u k    

®

Powrmatic Limited

Hort Bridge, Ilminster

Somerset

TA19 9PS

tel: 

+44 (0) 1460 53535

fax: 

+44 (0) 1460 52341

e-mail: 

[email protected]

web: 

www.powrmatic.co.uk

Powrmatic Ireland

45 Broomhill Close

Tallaght

Dublin 24

tel: 

+353 (0) 1452 1533

fax: 

+353 (0) 1452 1764

e-mail:

 [email protected]

web: 

www.powrmatic.ie

Getting In Touch

Powrmatic pursues a policy of continues improvement in both design and performance of its products and therefore reserves the right to change, amend or 

vary specifications without notice.  Whilst the details contained herein are believed to be correct they do not form the basis of any contract and interested 

parties should contact the Company to confirm whether any material alterations have been made since publication of this brochure.

EURO-AIR

QUALITY

ICOM

Energy Association

More information is available from our website by scanning the following QR code.

Doc Ref: M608 Issue 1.0 June 2021

Vision Mini

 

Installation & Servicing Manual

Issue 1.0  June 2021

Summary of Contents for Vision Mini

Page 1: ...w w w p o w r m a t i c c o u k Doc Ref M608 Issue 1 0 June 2021 Vision Mini Installation Servicing Manual Issue 1 0 June 2021 ...

Page 2: ...your behalf Conditions of Guarantee 1 The air conditioner must have been installed by a competent installer and in accordance with the manufacturer s instructions and any building regulations and local regulations 2 A copy of the registration form must be returned to Powrmatic 3 The air conditioner has been maintained on a yearly basis by a competent and qualified servicing company 4 The air condi...

Page 3: ...ctive and implementing regulation 206 2012 EU and Italian implementing regulation Legislative Decree no 15 of 16 02 2011 F Gas Regulation 2014 517 EU on fluorinated greenhouse gases And subsequent amendments For declarations of conformity certificates and other certification details please consult the website Dear Customer thank you for choosing Powrmatic We appreciate you buying one of our high q...

Page 4: ...14 2 6 Unpacking p 14 2 7 Handling without packaging p 15 2 8 Installation site p 15 2 9 Installation minimum distances p 16 2 10 Positioning p 16 2 11 Condensation drain preparation p 20 2 12 Electric connections p 22 2 13 High low installation configuration p 24 2 14 Setting cooling only or heating only mode p 25 2 15 Brightness control p 26 2 16 Touch screen display key lock p 26 2 17 hotel fun...

Page 5: ...page no 5 of 36 Vision Mini User Instructions Doc Ref M608 issue 1 0 June 2021 5 Technical information p 32 5 1 Technical data p 32 5 2 Dimensions p 33 5 3 RED Compliance Statement p 33 5 4 Safety p 33 ...

Page 6: ...flammable and odourless Avoid proximity to sources of ignition in continuous operation open flames gas appliances electric stoves lighted cigarettes etc Instructions Read the instructions carefully before performing any work on the appliance Instructions for Service The Technical Service Centre must read the instructions carefully before performing any work on the appliance Instructions for the us...

Page 7: ...ere is pressurised refrigerant gas and live electrical components inside the appliances The installation and subsequent maintenance phases must be carried out exclusively by authorised and qualified personnel Any contractual or extra contractual liability for damage caused to persons animals or property due to installation adjustment and maintenance errors or improper use is excluded All uses not ...

Page 8: ...em to off It is forbidden to modify the safety or adjustment devices or adjust without authorization and indications of the manufacturer It is forbidden to pull unplug or twist the device s electric cables even if it is disconnected from the mains It is forbidden to introduce objects and substances through the air inlet and outlet grilles It is forbidden to open the access doors of the device s in...

Page 9: ...refore invalidates the warranty 1 8 Destination of use These appliances have been designed for conditioning and or heating rooms and they must be destined solely for this purpose in accordance with their performance characteristics 1 9 Description of the appliance The 2 0 MINI 9 HP DC Inverter range of air conditioners without an external unit are designed for indoor installation on a perimeter wa...

Page 10: ...ti lifting bracket 11 External air expulsion 12 Remote control 13 Internal exchanger 14 External fan 15 Condensation pump 16 Condensation drain valve 17 Floater 18 External exchanger 19 External air probe 20 Room air probe 21 Compressor 1 6 2 3 9 11 13 12 10 8 4 7 5 5 14 15 16 17 18 19 21 20 1 11 Compatible accessories The accessories table refers to all products in the 2 0 range Please check the ...

Page 11: ...l L00771II Recessed formwork for corner installation with left hand exit Compatible with only DC Inverter versions All L00772II Accessories supplied separately Grilles and accessories Kit n 2 external grilles with fixed fins 160 mm for outdoor All GB0738II Rain protection kit Applicable only on fixed grids DN 160 mm All GB0739II Kit n 1 insect protection for intake hole only Can only be applied to...

Page 12: ...out to ensure that the risk of combustion is minimised before starting work on systems containing flammable refrigerants The appliance must be protected against accidental impacts to prevent mechanical damage Do not puncture or burn 2 2 Reception Preliminary warnings Upon receipt of the package check that it is not damaged otherwise accept the goods with reserve producing photographic evidence of ...

Page 13: ...und it when the load is lifted off the ground Avoid dangerous situations when using a hoist to lift the appliance During transportation the appliance must be kept in vertical position Avoid exposure to sources of ignition open flames lighted cigarettes sources of heat or sparks when opening the packaging Movement methods Boxes can either be carried singularly by hand by two operators or loaded on ...

Page 14: ...re The equipment must always be handled vertically Check if there is refrigerant inside the package using an electronic leak detector suitable for the system refrigerant If it is present the refrigeration circuit is likely damaged In this case do not install the appliance and call theTechnical Assistance Centre The packing material cardboard staples plastic bags etc must not be dispersed or abando...

Page 15: ...necessary to check carefully that the weight of the unit does not exceed the regulations in relation to the number of people used 2 8 Installation site The location of the appliance must be determined by the plant engineer or a competent person and must take into account both purely technical requirements and any national local legislation in force This appliance is designed for vertical low wall ...

Page 16: ...use damage to persons or property if it should detach from its base The unit should not be installed in a position where the air flow is aimed directly at the people nearby Provide the following a nearby drain for the outflow of condensate a compliant power supply nearby fixing elements suitable for the type of support Specific warnings for R290 The installation of the unit does not have any speci...

Page 17: ...cket hole A B C D E IN OUT Preliminary warnings The wall mounting bracket supplied as an accessory is required to position the unit on the wall Make sure that the wall supports the weight of the appliance the section of floor or wall does not concern piping or electrical lines the functionality of load bearing elements is not compromised Installation arrangement The units can be positioned on the ...

Page 18: ... the core drill to a vacuum system Proceed with caution in the vicinity of the outer wall in order to avoid the breakage of plaster around the hole Take precautions so that the drilled material does not fall on persons and objects below Positioning the ducts A Plastic sheet for ducts A measure the depth of the holes drilled in the wall subtract 5 mm from the measurement cut the plastic sheets supp...

Page 19: ...tension hook the chains to the counterflange cut off the excess of chain When painting the dampers use water based paints suitable for plastic surfaces to avoid problems with the move ment of the flaps Do not use thick sticky paints like enamels Fixing the bracket The devices are provided with metallic support for mounting on the wall 1 Spirit level 2 Metal support 3 Fixing screw 4 Support wall 5 ...

Page 20: ... If the line flows into a container e g a tank do not close the container hermetically and avoid immersing the draining pipe into the water The hole for the condensation pipe must always slope towards the outside The exact position in which to place the pipe mouth is indicated on the template Check that the expelled water does not cause any damage or problems to people or objects During winter thi...

Page 21: ...eakage of water The drainage pipe must be insulated for sections running inside houses in order to prevent condensate formation on its surface If needed it is possible to empty the condensation collection pan through a safety drain provided on the base of the devi ce See Chapter Extraordinary maintenance If using a jug for collecting the condensation Avoid the hermetic closure of the container Pre...

Page 22: ...e of minimum 3 mm or using a device enabling the complete disconnection of the appliance in overvoltage III category conditions Please check that the power supply is provided with suitable protections against overloads and or short circuits using a 10 AmpTime delay fuse or other equivalent devices is recommended To prevent any risk of electrocution always disconnect the main circuit breaker before...

Page 23: ...chapter Removal of aesthetic panels and grilles p 27 To access the connections unscrew the screws of the electrical panel remove the electrical panel cover Connection The appliance leaves the factory fully wired and equipped with a cable with Y type plug for connection to the power supply To power the unit simply insert the plug into a suitable socket protected by a circuit breaker 1 Main switch 2...

Page 24: ... the CP contact that places the device in standby and guarantees correct post ventilation GR Grey BR Brown YG Yellow Green BL Blue CP Presence contact G R G R C P G R BL YG BR Configuration with the nebulizer 3 0 When installing the nebulizer 3 0 it s very important to follow the indicated procedure to avoid a systematic alarm and the possible failure of the nebulizer This procedure enabled throug...

Page 25: ...Aesthetic lower cover kit Code GB0737II 2 Fixing screws supplied with the optional kit GB0737II 3 Right support bracket for the flap A B 1 3 2 180 Configuration After adjusting the air outlet flap position it is necessary to set up the electronic control of the appliance With the display on Keep pressed the button on the display for 10 seconds The symbol appears dn low wall flashing press again th...

Page 26: ...ey for 3 seconds The lock remains active also for the next operations performed via remote control and in the event of a power failure 2 17 hotel function Keep the key pressed for 10 seconds If the En function is enabled the dehumidification and Auto functions are disabled only ventilation heating and cooling are left on is reduced from 22 to 28 in cooling mode and from 16 to 24 in heating mode 2 ...

Page 27: ...08 issue 1 0 June 2021 2 19 Removal of aesthetic panels and grilles 2 1 2 20 Assembly of aesthetic panels and grilles To assemble positioning the aesthetic panel insert the two screws Screw in the two screws insert the filter insert the grid 2 1 Installation ...

Page 28: ...iances electric stoves lighted cigarettes etc Smoking in the vicinity of the appliance is prohibited Using a mobile phone near the appliance is prohibited Using leak detectors with halogen lamps is prohibited 3 2 Routine maintenance The routine maintenance plan includes the following cleaning operations External cleaning Clean the external surfaces with a soft damp cloth Do not use abrasive sponge...

Page 29: ...ic panels and grilles p 27 For grid assembly operations see chapter Assembly of aesthetic panels and grilles p 27 extract the filter by lifting it remove the dust from the filter with a vacuum cleaner or by washing it in running water allow it dry put the filters back on top of the coils taking care to position them correctly Do not use detergents or solvents After filter cleaning check if the pan...

Page 30: ...am irons hot plates etc Displayed faults In the event of a malfunction the display shows an alarm code The appliance still retains some functions see the OPERATION column Alarm Cause Function E1 Faulty room temperature RT sensor It is possible to normally activate the Cooling Dehumidification and Heating modes Regulation only monitors internal battery anti frost E2 Faulty internal coil IPT sensor ...

Page 31: ...ervice During heating condensation should drain freely through the specific pipe In the event of an alarm check that the condensation pipe is not bent or obstructed thus preventing the water from flowing out Use of the appliance Objects or structural obstacles furniture curtains plants leaves blinds etc must not obstruct the normal air flow both from the internal and from the external grids Do not...

Page 32: ...raulic data indoor Ventilation speed Nr 3 Air flow at the maximum fan speed m h 360 Air flow at the medium fan speed m h 300 Air flow at the minimum fan speed m h 240 Aeraulic data outdoor Ventilation speed Nr 3 Air flow at the maximum fan speed m h 430 Air flow at the medium fan speed m h 360 Air flow at the minimum fan speed m h 320 Electrical data total input power kW 0 90 Maximum absorbed curr...

Page 33: ...tal height mm 549 Total depth mm 165 Empty weight kg 38 0 Wall hole diameter mm 162 Wall holes distance mm 210 5 3 RED Compliance Statement Compliancewith2014 53 EURadioEquipmentDirective RED In accordance with Article 10 8 a and 10 8 b of the RED the following table provides information on the frequency bands used and the maximum RF transmit power of the product for sale in the EU Frequency range...

Page 34: ...page no 34 of 36 Vision Mini User Instructions Doc Ref M608 issue 1 0 June 2021 Notes ...

Page 35: ...page no 35 of 36 Vision Mini User Instructions Doc Ref M608 issue 1 0 June 2021 Notes ...

Page 36: ...4 e mail info powrmatic ie web www powrmatic ie Getting In Touch Powrmatic pursues a policy of continues improvement in both design and performance of its products and therefore reserves the right to change amend or vary specifications without notice Whilst the details contained herein are believed to be correct they do not form the basis of any contract and interested parties should contact the C...

Reviews: