Instruction Manual
189
Maintenance
Fault
Possible Cause
Probable Solution
Major Consideration
That Led to Solution
To Clear/Reset from
Fault Condition
Servo Connection
Fault!
Controller Firmware
has just been
updated
Reboot controller;
keep controller
off for at least 20
seconds
Servo Connection
Fault! on display
Reboot controller;
keep controller
off for at least 20
seconds
Spindle
Communications
Lead or trailing
controller is off
Turn lead or trailing
controller on
Spindle
Communications on
display
Turn lead or trailing
controller on
Controller is setup
as a lead or trailing
controller
Default the
controller
Controller is a
single spindle
Default the
controller
Ethernet cable
disconnected
Reconnect Ethernet
cable between
Lead and trailing
controllers
Visual/Mechanical
inspection to
ensure cable
connections are
tight
Reconnect Ethernet
cable between
Lead and trailing
controllers.
If using external
switches ensure
they are energized.
9.3 Message Guide
Message
Possible Cause
Probable Solution
Major Consideration
That Led to Solution
To Clear/Reset from
Message Condition
Communication
Fault
Cable has
disconnected from
controller or PI box
Reconnect cable
Visual inspection
Reconnect cable
Count Fault
Operator backed
out a fastener
Re-fasten loosened
fastener
Actual bolt count
on display is less
than required
Re-fasten loosened
fastener
Program Fault
Operator performed
a double hit or
fastened more
fasteners than was
expected
Reset Job or loosen
a secured fastener
to return to the
proper bolt count
Actual bolt count
on display is more
than required
Reset Job or loosen
a fastened fastener
Tool Update Failed
Tool INI file is
corrupt
Download a new
file and try to load
it again
Tool Update Failed
error message
appears.
Download a new
file and try to load
it again
Loss of
communication
between tool and
controller
See Tool
Communications! in
section “9.2.1 Fault
Guide” on page
181
Tool
Communications!
fault on display
See Tool
Communications! in
section “9.2.1 Fault
Guide” on page
181
PLC Message
The PLC is
providing the
message
None
PLC Message
is displayed on
controller
Press OK
Содержание QB Expert
Страница 8: ......
Страница 22: ... QB Expert Alpha Controller 14 5 7 8 5 7 6 8 1 2 4 1 3 Mounting QB Alpha Expert Controller onto Plinth ...
Страница 23: ...Introduction Instruction Manual 15 ...
Страница 24: ......
Страница 36: ......
Страница 37: ...3 QB Expert Alpha Controller Programming SETUP Area SERVICE Area ANALYZE Area ...
Страница 94: ......
Страница 109: ...Instruction Manual 101 ...
Страница 110: ......
Страница 123: ...Instruction Manual 115 Tool Operation ...
Страница 124: ......
Страница 132: ...Input and Output Connector QB Expert Alpha Controller 124 Inputs example ...
Страница 133: ...Controller Connections Instruction Manual 125 Outputs Sourcing example ...
Страница 157: ...Controller Connections Instruction Manual 149 ...
Страница 158: ...MODBUS TCP QB Expert Alpha Controller 150 ...
Страница 175: ...Embedded PLC Instruction Manual 167 ...
Страница 176: ......
Страница 177: ...8 QB Expert Alpha Controller Multiple Spindle Connection Disconnect Synchronization Networking ...
Страница 183: ...Multiple Spindle Instruction Manual 175 ...
Страница 184: ... QB Expert Alpha Controller 176 ...
Страница 201: ...Instruction Manual 193 Maintenance ...
Страница 202: ...QB Expert Alpha Controller 194 ...
Страница 203: ...10 QB Expert Alpha Controller Appendix A Torsion Compensation Angle Validation ...
Страница 206: ......
Страница 207: ...11 QB Expert Alpha Controller Glossary ...
Страница 210: ......