Instruction Manual
185
Maintenance
Fault
Possible Cause
Probable Solution
Major Consideration
That Led to Solution
To Clear/Reset from
Fault Condition
Temperature Fault!
Wrong value
in Temperature
parameter
Modify
Temperature
parameter value
Viewed
Temperature value
under SETUP->
OTHER-> TOOL tab
and compared with
Temperature value
on ANALYZE screen
Modify
Temperature
parameter value.
The maximum for
handheld tools
is 85˚C
. The
maximum for
fixtured tools is
125
˚
C.
Excessive duty cycle
Use a larger tool for
the job
Tool is hot to touch
and shuts down:
QPM tools
shutdown when
tool internal
temperature
reaches and stays
above programmed
set point for 8
minutes
This error
automatically resets
when temperature
drops and stays
below trip point for
8 minutes on QPM
tools.
It can also be reset
by cycling power,
however, if the
tool has not cooled
down this error
will reappear in 8
minutes.
For fixtured tools
turn off
Soft Stop
.
Inefficient
Rundown Strategy
Contact STANLEY
Assembly
Technologies for
help on modifying
strategy
Tool is hot to touch
and shuts down:
QPM tools
shutdown when
tool internal
temperature
reaches and stays
above programmed
set point for 8
minutes
To prevent an
over temperature,
modify the
strategy by raising
downshift speed
or eliminating the
downshift; Also
try a multi-step
strategy with a
Delay Between
Steps
of at least
0.5 seconds.
For fixtured tools
turn off
Soft Stop
.
Содержание QB Expert
Страница 8: ......
Страница 22: ... QB Expert Alpha Controller 14 5 7 8 5 7 6 8 1 2 4 1 3 Mounting QB Alpha Expert Controller onto Plinth ...
Страница 23: ...Introduction Instruction Manual 15 ...
Страница 24: ......
Страница 36: ......
Страница 37: ...3 QB Expert Alpha Controller Programming SETUP Area SERVICE Area ANALYZE Area ...
Страница 94: ......
Страница 109: ...Instruction Manual 101 ...
Страница 110: ......
Страница 123: ...Instruction Manual 115 Tool Operation ...
Страница 124: ......
Страница 132: ...Input and Output Connector QB Expert Alpha Controller 124 Inputs example ...
Страница 133: ...Controller Connections Instruction Manual 125 Outputs Sourcing example ...
Страница 157: ...Controller Connections Instruction Manual 149 ...
Страница 158: ...MODBUS TCP QB Expert Alpha Controller 150 ...
Страница 175: ...Embedded PLC Instruction Manual 167 ...
Страница 176: ......
Страница 177: ...8 QB Expert Alpha Controller Multiple Spindle Connection Disconnect Synchronization Networking ...
Страница 183: ...Multiple Spindle Instruction Manual 175 ...
Страница 184: ... QB Expert Alpha Controller 176 ...
Страница 201: ...Instruction Manual 193 Maintenance ...
Страница 202: ...QB Expert Alpha Controller 194 ...
Страница 203: ...10 QB Expert Alpha Controller Appendix A Torsion Compensation Angle Validation ...
Страница 206: ......
Страница 207: ...11 QB Expert Alpha Controller Glossary ...
Страница 210: ......