Controller Connections
Instruction Manual
141
Outputs
Description
*PARAMETER
This output is the value of the selected Parameter. It changes when the parameter changes.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Configuration:
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Parameter: Strategy, Torque Target, High Torque, Low Torque, Angle Target, High Angle, Low Angle, Snug
Torque, Speed, Step Name, Torque Cal, Tool Serial Number, Torque Bailout, Angle Bailout, Downshift Torque,
Downshift Speed, Tool Model Number, Task Name, Job Name, Task Bolt Count.
Step: Audit, Audit-1, Audit-2
Spindle: Type the spindle number from which the signal comes.
*PART ID
This value is equal to and changes as the PART ID input changes.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Configuration:
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Spindle: Type the spindle number from which the signal comes.
PM
Asserts when the Preventive Maintenance Count in the tool’s memory has exceeded the Preventive Maintenance
Threshold. Resets when the Preventive Maintenance Count is reset to zero.
Size: 1 bit
Configuration:
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the signal comes.
READY
Asserts when there is no fault on the controller and the tool is ready to run. This output resets when the tool is
disabled. The blue light on the controller and tool will illuminate when this output is on.
Size: 1 bit
Configuration:
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the signal comes.
*RUNDOWN BOLT
This is the accumulated bolt count value of the last fastening cycle. It asserts when the fastening cycle is
complete (after the IN CYCLE bit resets). The value resets to zero (0) when the tool is commanded to run again.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Configuration:
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Spindle: Type the spindle number from which the signal comes.
*RUNDOWN DAY
This is the day value of the last fastening cycle date. It asserts when the fastening cycle is complete (before the
IN CYCLE bit resets). The value resets to zero (0) when the tool is commanded to run again.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Configuration:
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Spindle: Type the spindle number from which the signal comes.
Содержание QB Expert
Страница 8: ......
Страница 22: ... QB Expert Alpha Controller 14 5 7 8 5 7 6 8 1 2 4 1 3 Mounting QB Alpha Expert Controller onto Plinth ...
Страница 23: ...Introduction Instruction Manual 15 ...
Страница 24: ......
Страница 36: ......
Страница 37: ...3 QB Expert Alpha Controller Programming SETUP Area SERVICE Area ANALYZE Area ...
Страница 94: ......
Страница 109: ...Instruction Manual 101 ...
Страница 110: ......
Страница 123: ...Instruction Manual 115 Tool Operation ...
Страница 124: ......
Страница 132: ...Input and Output Connector QB Expert Alpha Controller 124 Inputs example ...
Страница 133: ...Controller Connections Instruction Manual 125 Outputs Sourcing example ...
Страница 157: ...Controller Connections Instruction Manual 149 ...
Страница 158: ...MODBUS TCP QB Expert Alpha Controller 150 ...
Страница 175: ...Embedded PLC Instruction Manual 167 ...
Страница 176: ......
Страница 177: ...8 QB Expert Alpha Controller Multiple Spindle Connection Disconnect Synchronization Networking ...
Страница 183: ...Multiple Spindle Instruction Manual 175 ...
Страница 184: ... QB Expert Alpha Controller 176 ...
Страница 201: ...Instruction Manual 193 Maintenance ...
Страница 202: ...QB Expert Alpha Controller 194 ...
Страница 203: ...10 QB Expert Alpha Controller Appendix A Torsion Compensation Angle Validation ...
Страница 206: ......
Страница 207: ...11 QB Expert Alpha Controller Glossary ...
Страница 210: ......