Controller Connections
Instruction Manual
127
Please see the full description of each function in the section following this table.
Inputs
Description
Configuration Options
DISABLE JOB
Disable the job
Contact Type, Job, Spindle
DISABLE TASK
Disable the task
Contact Type, Task, Spindle
DISABLE TOOL
Disable tool (will complete running if it is in cycle)
Contact Type , Spindle
IGNORED
Input is not used
Input is not assigned
JOB VERIFY
Verify the selected job to the inputs
Contact Type, Job, Spindle
JOB VERIFY (BIT)
Verify the selected job to one of the input bits in a series
Contact Type, Bit, Mode, Spindle
PART ID
Sets the part identification
Length, Trigger, Spindle
RESET JOB
Reset a job
Contact Type , Spindle
RESET RESULT STATUS
Clear the result status
Contact Type , Spindle
REVERSE
Put the tool in reverse
Contact Type , Spindle
SELECT JOB
Select a job
Contact Type, Job, Disable when open,
Spindle
SELECT JOB (BIT)
One bit in a series to select the job
Contact Type, Bit, Mode, Spindle
SELECT TASK
Select a task
Contact Type, Task, Disable When Open,
Spindle
SELECT TASK (BIT)
One bit in a series to select the task
Contact Type, Bit, Mode, Spindle
SET ZERO POSITION
Used to set Zero Position for Position Control Strategy
Contact Type, Spindle
START
Start the tool
Contact Type, Latch, Time, Spindle
START REVERSE
Put the tool in reverse and start the tool
Contact Type , Spindle
STOP
Stop the tool
Contact Type , Spindle
TASK VERIFY
Verify the selected task to the inputs
Contact Type, Task, Spindle
TASK VERIFY (BIT)
Verify the selected task to one of the input bits in a
series
Contact Type, Bit, Mode, Spindle
* Input not available on 24V
Outputs
Description
Configuration Options
*ANGLE
Angle result value
Data Type, Step, Spindle
ANGLE HIGH
Fastening cycle Angle exceeded High limit
Contact Type, Type, Time, Step, Spindle
ANGLE LOW
Fastening cycle Angle under Low limit
Contact Type, Type, Time, Step, Spindle
ANGLE OK
Fastening cycle Angle was within limits
Contact Type, Type, Time, Step, Spindle
*ANGLE STATUS
Angle status of last fastening cycle
Data Type, Step, OK, Low, High, Spindle
*BOLT
Active Accumulated Bolt Count
Data Type, Spindle
*CONSTANT
User defined value
Data Type, Constant
CYCLE ABORTED
The fastening cycle was aborted/stopped
Contact Type, Type, Time, Spindle
CYCLE NOK
Fastening cycle was NOK
Contact Type, Type, Time, Spindle
Содержание QB Expert
Страница 8: ......
Страница 22: ... QB Expert Alpha Controller 14 5 7 8 5 7 6 8 1 2 4 1 3 Mounting QB Alpha Expert Controller onto Plinth ...
Страница 23: ...Introduction Instruction Manual 15 ...
Страница 24: ......
Страница 36: ......
Страница 37: ...3 QB Expert Alpha Controller Programming SETUP Area SERVICE Area ANALYZE Area ...
Страница 94: ......
Страница 109: ...Instruction Manual 101 ...
Страница 110: ......
Страница 123: ...Instruction Manual 115 Tool Operation ...
Страница 124: ......
Страница 132: ...Input and Output Connector QB Expert Alpha Controller 124 Inputs example ...
Страница 133: ...Controller Connections Instruction Manual 125 Outputs Sourcing example ...
Страница 157: ...Controller Connections Instruction Manual 149 ...
Страница 158: ...MODBUS TCP QB Expert Alpha Controller 150 ...
Страница 175: ...Embedded PLC Instruction Manual 167 ...
Страница 176: ......
Страница 177: ...8 QB Expert Alpha Controller Multiple Spindle Connection Disconnect Synchronization Networking ...
Страница 183: ...Multiple Spindle Instruction Manual 175 ...
Страница 184: ... QB Expert Alpha Controller 176 ...
Страница 201: ...Instruction Manual 193 Maintenance ...
Страница 202: ...QB Expert Alpha Controller 194 ...
Страница 203: ...10 QB Expert Alpha Controller Appendix A Torsion Compensation Angle Validation ...
Страница 206: ......
Страница 207: ...11 QB Expert Alpha Controller Glossary ...
Страница 210: ......