Assignable Input and Output Functions
QB Expert Alpha Controller
140
Outputs
Description
JOB COMPLETE
Asserts when a job is completed (accumulated bolt count equals target bolt count). Resets when a different job
is selected or when the input RESET JOB is asserted.
Size: 1 bit
Configuration:
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the signal comes.
JOB SELECTED
Asserts when a job is selected by any means. Resets when the active job is complete.
Size: 1 bit
Configuration:
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Job: Type the job number that, when selected, asserts this output.
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the signal comes.
JOB SELECTED BIT
Asserts when required to indicate the active job. This is one bit in a series of bits to create a binary number. As
jobs change so will the binary number created from these bits.
Size: 1 bit
Configuration:
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Bit: Type the number this bit to be in the binary number scheme for selected jobs.
Mode: All JOB SELECTED BITs must be the same mode, modes cannot be mixed.
Binary – Creates a decimal number equivalent to the weighted value of this binary bit(s).
1 – Creates a number equivalent to the weighted value of this binary bit(s) and adda the value
of one (1) to that number.
Spindle: Type the spindle number from which the signal comes.
MULTI-FUNCTION
BUTTON
Asserts when the tool’s Multi-function Button is pressed. Resets when the Multi-function Button is released.
Size: 1 bit
Configuration:
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the signal comes.
NOT USED
The output is not used. This is essentially a placeholder.
For fieldbus, the length of this input function may be set to any size that meets the need.
Содержание QB Expert
Страница 8: ......
Страница 22: ... QB Expert Alpha Controller 14 5 7 8 5 7 6 8 1 2 4 1 3 Mounting QB Alpha Expert Controller onto Plinth ...
Страница 23: ...Introduction Instruction Manual 15 ...
Страница 24: ......
Страница 36: ......
Страница 37: ...3 QB Expert Alpha Controller Programming SETUP Area SERVICE Area ANALYZE Area ...
Страница 94: ......
Страница 109: ...Instruction Manual 101 ...
Страница 110: ......
Страница 123: ...Instruction Manual 115 Tool Operation ...
Страница 124: ......
Страница 132: ...Input and Output Connector QB Expert Alpha Controller 124 Inputs example ...
Страница 133: ...Controller Connections Instruction Manual 125 Outputs Sourcing example ...
Страница 157: ...Controller Connections Instruction Manual 149 ...
Страница 158: ...MODBUS TCP QB Expert Alpha Controller 150 ...
Страница 175: ...Embedded PLC Instruction Manual 167 ...
Страница 176: ......
Страница 177: ...8 QB Expert Alpha Controller Multiple Spindle Connection Disconnect Synchronization Networking ...
Страница 183: ...Multiple Spindle Instruction Manual 175 ...
Страница 184: ... QB Expert Alpha Controller 176 ...
Страница 201: ...Instruction Manual 193 Maintenance ...
Страница 202: ...QB Expert Alpha Controller 194 ...
Страница 203: ...10 QB Expert Alpha Controller Appendix A Torsion Compensation Angle Validation ...
Страница 206: ......
Страница 207: ...11 QB Expert Alpha Controller Glossary ...
Страница 210: ......