9. FAULT DIAGNOSIS
SYMPTO
M
POSSIBLE CAUSE
REMEDY
PAGE REF.
Placing Tool will not
operate
Inoperative pump unit
Check pump power supply and refer to
pump unit instruction manual
Faulty Quick Couplers
10
and
11
Replace Quick Couplers
Trigger Control Cable
14
not
connected correctly
Check Control Cable is correctly connected
at pump and placing tool
Damaged Trigger Switch
7
or
Control Cable
14
Replace Trigger Switch and/or Control
Cable
Trigger Switch
7
does not
function
Pump in local mode
Refer to pump instruction manual
Trigger Switch
7
, Control Cable
14
or connector damaged
Replace Trigger Switch and/or Control
Cable
Pump running but
placing tools does not
function
Hydraulic Hoses not connected
Check for correct connections at pump and
placing tool
Low oil level
Ensure placing tool is filled with oil and
correctly primed.
Refer to pump instruction manual
Placing tool external oil leak
Inspect placing tool – replace worn or
damaged components
Hose Assembly external oil leak
Inspect Hose Assembly – ensure hose
connections are tight and/or replace
damaged hose connectors
Pump internal/external oil leak
Refer to pump instruction manual
Placing tool operates
erratically
Low or erratic hydraulic pressure
supply
Refer to pump instruction manual
Worn or damaged hydraulic seals in
placing tool
Inspect placing tool – replace worn or
damaged seals
Worn or damaged hydraulic
sealing surfaces in placing tool
Inspect placing tool – replace
worn or damaged components
Pump internal/external oil leak
Refer to pump instruction manual
Pump builds full
pressure, but pintail does
not break
Breakload greater than placing tool
capacity at full pressure
Refer to placing tool specification
Flow to placing tool blocked
Check Quick Couplers
10
and
11
for full engagement
Pump pressure relief value set too
low
Adjust pressure relief valve settings – refer
to pump instruction manual
Pull grooves on fastener pintail
stripped
See symptom on page 20
Improper tool operation
Placing tool Piston
1
will not return
Return flow restricted or blocked
Check Quick Couplers
10
and
11
for full
engagement and/or fault
Hydraulic Hoses not connected
Check for correct connections at pump and
placing tool
Pump valve malfunction
Refer to pump instruction manual
20
ENGLISH
Содержание AV 10
Страница 15: ...6 GENERAL ASSEMBLY OF INSTALLATION TOOL 73430 02000 3 4 2 5 1 7 8 9 10 11 13 14 12 6 15 ENGLISH ...
Страница 39: ...6 PLAN D ENSEMBLE GÉNÉRAL DE L OUTIL DE POSE 73430 02000 3 4 2 5 1 7 8 9 10 11 13 14 12 6 15 FRANÇAIS ...
Страница 50: ......
Страница 65: ...6 ALLGEMEINE MONTAGE DES SETZWERKZEUGS 73430 02000 3 4 2 5 1 7 8 9 10 11 13 14 12 6 15 DEUTSCH ...
Страница 89: ...6 DISEGNO ESPLOSO DELL UTENSILE DI INSTALLAZIONE 73430 02000 3 4 2 5 1 7 8 9 10 11 13 14 12 6 15 ITALIANO ...
Страница 100: ......
Страница 115: ...6 OGÓLNY WIDOK MONTAŻOWY NARZĘDZIA INSTALACYJNEGO 73430 02000 3 4 2 5 1 7 8 9 10 11 13 14 12 6 15 POLSKI ...
Страница 139: ...6 BLOQUE GENERAL DE LA REMACHADORA 73430 02000 3 4 2 5 1 7 8 9 10 11 13 14 12 6 15 ESPAÑOL ...
Страница 150: ......
Страница 166: ...6 ALGEMENE MONTAGE VAN INSTALLATIEGEREEDSCHAP 73430 02000 3 4 2 5 1 7 8 9 10 11 13 14 12 6 16 NEDERLANDS ...
Страница 190: ...6 GENEREL MONTERING AF INSTALLATIONSVÆRKTØJ 73430 02000 3 4 2 5 1 7 8 9 10 11 13 14 12 6 14 DANSK ...
Страница 200: ......
Страница 214: ...6 ASENNUSTYÖKALUN LAITEKAAVIO 73430 02000 3 4 2 5 1 7 8 9 10 11 13 14 12 6 14 SUOMI ...
Страница 224: ......
Страница 238: ...6 GENERELL MONTERING AV VERKTØYET 73430 02000 3 4 2 5 1 7 8 9 10 11 13 14 12 6 14 NORSK ...
Страница 248: ......
Страница 262: ...6 ALLMÄN MONTERING AV INSTALLATIONSVERKTYG 73430 02000 3 4 2 5 1 7 8 9 10 11 13 14 12 6 14 SVENSKA ...
Страница 272: ......
Страница 287: ...6 MONTAGEM GERAL DA FERRAMENTA DE INSTALAÇÃO 73430 02000 3 4 2 5 1 7 8 9 10 11 13 14 12 6 15 PORTUGUÊS ...
Страница 298: ......
Страница 299: ......