8
Example – Multiple line system
Use of at least 2 but no more than
15 bus lines.
Installation example
The Siedle call station comprises
2 door stations (main and side
entrance), 2 indoor stations (storey 0
and 1), 1 Gateway and 2 bus video
line rectifiers.
The Siedle intercom is supplied via
the first bus line and the Gateway
via the second bus line.
Calculation
of the additional bus addresses
which can be used in the Gateway:
1. Bus line
Components
Bus
adresses
Door call station Main
entrance
2
Door call station Side
entrance
2
Internal call station
1
1
Internal call station 2
1
Sum
6
Max. number of bus
addresses per bus line
31
Additionally usable free
bus addresses
25
2. Bus line
Components
Bus
adresses
Gateway
1
Max. number of bus
addresses per bus line
31
Additionally usable free
bus addresses
30
The result: A maximum of 31
bus addresses can be used in the
Gateway for the connection of
IP users or IP groups (30 free bus
add 1 already assigned
bus address of the Gateway).
Example – Single line system
Use of one bus line
.
Installation example
The Siedle call station comprises
2 door stations (main and side
entrance), 2 indoor stations (storey 0
and 1), 1 Gateway and 1 bus video
line rectifier.
Calculation of the additional bus
addresses which can be used in the
Gateway:
1. Bus line
Components
Bus
adresses
Door call station Main
entrance
2
Door call station Side
entrance
2
Internal call station
1
1
Internal call station 2
1
Gateway
1
Sum
7
Max. number of bus
addresses per bus line
31
Additionally usable free
bus addresses
24
The result: A maximum of 25
bus addresses can be used in the
Smart Gateway for the connec
-
tion of IP users or IP groups (24
free bus add 1 already
assigned bus address of the
Smart Gateway).
System limits
Gateway
Characteristics:
Quantity
Maximum number of
assignable bus addresses
31
Maximum amount of
IP users per gateway
(5 user licenses for a total
of 5 IP users are included
in the scope of delivery of
the gateway). From device
version 2.0.1, Siedle Axiom
and the JUNG TKM client
no longer require user
licenses.
10
Maximum number of IP
groups
–
Maximum number of IP
users per IP group
6
Cascading: IP group in IP
group
0
With an In-Home bus address, you
can:
• Selectively call 1 IP user individually
through the In-Home bus (e.g. door
station)
or
• Selectively call 1 IP group (with a
maximum of 6 IP users) individually
through the In-Home bus (e.g. door
station).
With 31 In-Home bus addresses,
you can:
• Selectively call 31 IP users individ-
ually through the In-Home bus (e.g.
door station)
or
• Selectively call 31 IP groups (with a
maximum of 6 IP users) individually
but in total no more than 10 IP users
per Gateway through the In-Home
bus (e.g. door station)
or
• In a mixed configuration with a
maximum of 10 IP users, selectively
call individual IP users or IP groups
(with a maximum of 6 IP users)
through the In-Home bus (e.g. door
station)
Overview