14
Fulfilling commissioning
requirements
In order to allow the Gateway to be
commissioned, the following work
must have been completed:
1
The door intercom system has
been correctly installed/mounted
in accordance with the In-Home
bus: Video system manual and has
been prepared with a programming
interface for programming using a
PC/laptop (does not apply when pro-
gramming manually).
2
The geographical position of all
devices and all required button
assignments/functions for the indi
-
vidual devices are documented.
3
A commissioning PC/laptop with
the latest version of the BPS pro
-
gramming software installed is avail-
able for commissioning.
4
Network information is available.
5
The commissioning technician has
knowledge of network technology.
6
The commissioning laptop/PC
automatically refers to its IP address
(DHCP = active).
7
The intercom has been completely
documented for the In-Home bus
and for the IP network.
8
The Gateway has been mounted,
is ready for operation, connected
to the In-Home bus and the com-
missioning laptop/PC (directly by
LAN cable or via a DHCP-capable IP
network).
9
The commissioning laptop (USB)
and the bus video line rectifier (RJ45)
have been connected via the pro
-
gramming interface (USB/RJ45).
10
The Gateway has been registered
with Siedle:
www.siedle.com/mysiedle
11
Any existing updates have been
saved on the commissioning laptop.
12
The bus programming software
BPS 650-0 is ready for operation
and there is an active connection to
the bus video line rectifier (does not
apply when programming manually).
Register product
Siedle software is continuously
updated and further developed. To
ensure that you make use of all the
product benefits and to obtain reg-
ular future updates, we recommend
that you register your product in the
My Siedle Service Portal:
www.siedle.com/mysiedle
For registration, you require
the MAC address (hardware
address of the Gateway: e.g.
00:10:20:30:a1:b2).
The MAC
address of the Gateway can be
found on the packaging, on the
device sticker and in the device
information of the browser-based
user interface.
Procedure:
1
Register your Gateway on the
mysiedle service portal.
2
Download existing system updates
and save these on your commis
-
sioning laptop.
Downloading and installing the
bus programming software
For bus programming of the
Gateway, you will need the bus
programming software BPS 650.
In
order to determine the IP address
of the Gateway, you will require the
Siedle Finder.
The Siedle Finder is
installed at the same time as the bus
programming software.
The bus pro
-
gramming software can be down-
loaded under
www.siedle.com
.
Procedure:
1
Download the bus programming
software completely to your com-
missioning laptop/PC.
2
Install the bus programming
software completely on your com-
missioning laptop/PC.
Step-by-step through the
commissioning process
The following commissioning steps
are described over the following
pages:
1
Register product
2
Define the type of programming
(manual programming or program-
ming using the bus programming
software).
3
Establish the network connection
to the Gateway (directly using the
LAN cable (Zero Configuration
Networking) or indirectly using a
DHCP-capable IP network).
4
Downloading and installing the
bus programming software (
Only
when programming with bus pro-
gramming software).
5
Program/configure the In-Home
bus with the bus programming soft-
ware or with manual programming.
6
Configure the Gateway
7
Install, configure and commission
the Siedle app on the terminals.
8
Complete function check
9
Hand over the complete docu-
mentation, system backups and
updates to the customer / system
administrator.
10
Instruct the customer to issue
a new and secure password which
must not be known to the person
carrying out the commissioning.
Important:
Observe all safety and
warning instructions! Also observe
all other instructions in this docu
-
ment.
Commissioning requirements