13
Commissioning requirements
Standard login data/
Known login data
Standard user name: admin
Standard password:
admin
Required network properties
Direct LAN connection between the Gateway and commissioning laptop/PC
(zero configuration networking: 169.254.1.1) or DHCP-capable network for
initial commissioning.
For regular operation, a permanent static IP address
is required. This ensures that the Gateway can always be reached under the
same IP address.
Otherwise, find out the IP address of the Gateway either
using the Siedle Finder or the bus programming software, via the router/Wi-Fi
router/managed switch/server in the area Network/Network settings with the
aid of a dedicated network scanner.
Time setting
• Manual time settings: If there is no facility for automatic time setting,
the time must be entered manually.
•
Automatic time setting: You will require an internet connection to a time
server in the internet or the address of an internal time server in the LAN
in order to adjust this during the configuration.
This data must be made
available by the customer/system administrator.
Remark:
If the Automatic option has not been selected for Time/date,
then the time must be reset after each power failure or reset, as there is no
buffer battery.
Alternatively, you can operate the Gateway with manual time
setting at an uninterruptible power supply.
Sufficient number of user licences
For each IP user (Siedle app, etc.) one user licence is required.
There are 5 user licences contained in the scope of supply.
Other user licences can be ordered under
www.siedle.com/mysiedle
.
Necessary commissioning software
•
Bus programming software BPS 650-0
– Version:
(
Latest edition
)
The bus programming software can be downloaded under
www.siedle.com
.
•
Siedle finder (component of the bus programming software installation)
•
Standard web browser (latest version)
Required documentation
• Product information
Smart Gateway Professional SG 150-0
• Commissioning instruction
•
System Manual In-Home bus: Video (
Latest edition
)
Required hardware
• Commissioning laptop/PC
•
Network cable (RJ45)
•
USB cable (A->B)
• Programming interface
PRI 602-… USB
•
Bus supply unit accessory ZBVG 650-…
Local access points
•
Local access to the bus video line rectifier and Gateway
•
RJ45 connection to the DHCP-capable LAN/IP network,
which is located in the direct vicinity of the Gateway.
Necessary operating software/apps
•
Siedle App for use on smartphones with Android/iOS operating system.
Download: Via your terminal with access to the App Store.
Commissioning requirements