15
4 s
OFF
1 s
ER
T
ET
b
Tb
M
S1 S1
– +
E1 E1
PE PE
Ta
M
0000000000000
Smart Gateway
SG 150-0
IP 20
www.siedle.com
Link
In-Home
Status
Reset
Prog.
3 s
ON
1 s
4 s
5
The call button is now assigned
to the Gateway and the basic func-
tions of the In-Home bus are set up.
Program additional users using the
same procedure or quit the pro
-
gramming mode.
3
The In-Home LED at the Gateway
lights up in green (ready for oper-
ation). Press the Prog. button at
the Gateway for 3 seconds. The
In-Home LED then flashes green.
Manual programming
Procedure:
On principle, the In-Home bus can
be commissioned and programmed
by one person. However, as work
has to be executed both at the door
loudspeaker and the bus indoor
device, we recommend that commis-
sioning be carried out by two people
for larger-scale projects.
2
At the door station, hold down
the light/programming button for
4 seconds. A protracted acknowl-
edgement tone is then audible
which is repeated every 5 seconds
as long as the programming mode
remains active.
1
Switch on the programming mode.
At the BNG/BVNG 650-…, press the
programming mode button briefly.
The LED 1 flashes in a 2-second
rhythm to indicate that the program
-
ming mode is active.
4
On the door station, press and
hold the desired call button for
4 seconds until a sustained tone can
be heard from the door loudspeaker.
The call button is now assigned to
the bus indoor device.
• Complete the installation
• Check the switch positions at the
BNG/BVNG 650-…, in new systems
set the switch setting to Norm.
• Activate the programming mode
at the bus line rectifier
• Set the door station to the pro
-
gramming mode
• Program the users
• Quit the programming mode
While the bus line rectifier is in the
programming mode, several steps
can be programmed in sequence.
There is no need to quit the pro
-
gramming mode after every oper
-
ation.
Commissioning