Shock pulse measurement
Transducer with quick connector
The choice of transducer type depends on how the measuring
point is prepared. For systematic shock pulse monitoring,
SPM recommends the use of installed adapters and the quick
connect transducer wherever possible.
All three types of shock pulse transducers are connected to
Leonova’s ‘SPM’ connector (1).
DuoTech
®
accelerometer with quick connector
The DuoTech
®
accelerometer with quick connector TRC10 is
connected to Leonova’s ‘VIB’ connector (B) via measuring cable
CAB82. The accelerometer fits all standard SPM measuring
adapters and measures shock pulse and vibration in combination.
Adapters are solid metal bolts of different lengths and thread
sizes, tuned for correct signal transmission. They are installed in
threaded, countersunk mounting holes on the bearing housings.
Glue-on adapters are available.
To attach a transducer with quick connector, press it against
the adapter and twist clockwise. Twist counter-clockwise to
remove it.
Check that installed transducers and adapters are properly
mounted according to the SPM installation instructions and in
good condition. You cannot expect a useful signal by attaching
the quick connect transducer to a rusty lump of metal, or from
a transducer that is rolling on the floor on the other side of a
partition.
Adapter surfaces must be clean and plane. Use an adapter
cap to protect them.
A CondID
®
tag
(an RFID identification tag) can be hung on the
adapter cap. CondID
®
is a contact free memory tag used for
measuring point recognition. It should not be mounted flat
against a metal surface. A distance of min. 3 mm between
metal surfaces and CondID
®
is recommended.
CondID
®
responds to a recognition signal when Leonova is held
close to the tag. It contains all basic data for its measuring
point. If the measuring point is already loaded in Leonova, it
will be displayed, else it will be added to those in the data
logger memory.
Push and twist
Signal transmission
Adapter cap
Identification
tag, CondID
1
Содержание leonova emerald
Страница 1: ...User guide PORTABLE EFFICIENCY ...
Страница 2: ......
Страница 6: ...A 2 General instrument functions A ...
Страница 36: ...B 2 General measurement functions B ...
Страница 74: ...C 2 Measurement techniques always included B C ...
Страница 88: ...D D 2 Shock pulse measurement ...
Страница 122: ...D D 36 Shock pulse measurement ...
Страница 124: ...E E 2 Vibration measurement ...
Страница 150: ...E E 28 Vibration measurement ...
Страница 152: ...F F 2 Rotor balancing ...
Страница 170: ...F F 20 Rotor balancing ...