E
E:12
Vibration measurement
Measurement results, ISO 10816
Depending on the part of the standard and
the machine group, ISO 10816 gives limit
values for displacement (DISP) and either
velocity (VEL) or acceleration (ACC). Leonova
automatically adjusts the measurement quan-
tity display to the selected part and group
In this case, Leonova will display the evalu-
ated result in DISP, VEL and ACC, because all
three parameters are returned when Part 6 is
selected.
In case the different parameters fall into
different evaluation zones, the large status dot
(1) will show the worst case, while the small
status dots (2) show the individual evaluation.
Press F1 to see the ‘Measuring result’ window.
The spectrum (3) is always a velocity spectrum.
For spectrum functions in Leonova, see part B
of this manual.
Pressing F4 (4) toggles between Hz, CPM and,
if rpm is measured, orders.
To save the measuring result, press MENU
and select ‘Save as’. The measurement can be
saved as a result file or as a file with default
settings.
3
4
2
1