A:30
General instrument functions
A
Vibration severity ISO 2372
Measurement
quantities:
velocity, RMS value in mm/s
over 10 to 1000 Hz
Evaluation table
selection:
menu guided, ISO 2372
Transducer line test:
bias voltage test
Vibration severity ISO 10816 with spectrum
Measurement
quantity:
velocity, acceleration, and
displacement according
to individual parts in the
standard
Spectrum,
linear, 1600 lines, Hanning
window.
Quick mode:
yes (can be set ON/OFF)
Transducer line test:
bias voltage test
HD ENV
Spectrum lines, frequency and envelope filter limits are
regulated by what is included in the vibration package.
Frequency limit, upper:
stated in orders
Envelope high pass filters: 100, 200, 500, 1000, 2000,
5000, 10 000 Hz
Envelope band pass filters: Filter 1 = 5 -100 Hz
Filter 2 = 50 -1000 Hz
Filter 3 = 500 -10 000 Hz
Filter 4 = 5000 - 40 000 Hz*
Averages:
Time synch
Spectrum lines:
400, 800, 1600, 3200, 6400,
12800
Frequency units:
Hz, CPM, orders
Saving options:
full spectrum, time signal and
FFT, condition parameters
Vibration analysis, EVAM / FFT with symptoms
Frequency limit,
lower:
0 (DC) to 200 Hz
Frequency limit,
upper:
8 to 20 000 Hz (EVAM)
8 to 10 000 Hz (FFT)
order tracking
Envelope high
pass filters:
100, 200, 500, 1000, 2000,
5000, 10 000 Hz
Envelope band
pass filters:
5-100, 50-1000, 500-10 000,
5000-40 000 Hz
Measurement
windows:
Rectangle, Hanning,
Hamming, Flat Top
Averages:
time synchronous, FFT linear,
FFT peak-hold
Spectrum lines, EVAM:
400, 800, 1600, 3200, 6400,
12800
Spectrum lines, FFT:
400, 800, 1600, 3200, 6400
Saving options:
time signal (FFT calculated),
full spectrum, time signal and
FFT, condition parameters
Spectrum types
displayed:
linear, power, PSD
Zoom, EVAM:
true FFT zoom, visual zoom
Zoom, FFT:
visual zoom
Quick mode:
yes (can be set ON/OFF)
Frequency units:
Hz, CPM, orders
Trigger selection:
RPM trigger, post trigger
Transducer line test:
bias voltage test
* Integral Electronic PiezoElectric
Specifications are subject to change without notice.
Содержание leonova emerald
Страница 1: ...User guide PORTABLE EFFICIENCY ...
Страница 2: ......
Страница 6: ...A 2 General instrument functions A ...
Страница 36: ...B 2 General measurement functions B ...
Страница 74: ...C 2 Measurement techniques always included B C ...
Страница 88: ...D D 2 Shock pulse measurement ...
Страница 122: ...D D 36 Shock pulse measurement ...
Страница 124: ...E E 2 Vibration measurement ...
Страница 150: ...E E 28 Vibration measurement ...
Страница 152: ...F F 2 Rotor balancing ...
Страница 170: ...F F 20 Rotor balancing ...