IM-P198-05
MI Issue 2
122
Pressure transducer ranges
Pressure sensor ranges(1), bar a (psi a)
Full scale operating pressure
Maximum over-range pressure
bar a
psi a
bar a
psi a
2
30
4
60
7
100
14
200
20
300
41
600
34
500
69
1000
100
1500
175
2500
Note:
(1)
To maximize accuracy, specify the lowest full scale operating pressure range for the
application. To avoid damage, the flowmeter must never be subjected to pressure above the
over-range pressure shown above.
Power
requirements
12 to 36 Vdc, 25 mA, 1 W max., Loop Powered Volumetric or Mass 12 to
36 Vdc, 300 mA, 9 W max. Multiparameter Mass options 100 to 240 Vac,
50/60 Hz, 5 W max. Multiparameter Mass options
Class I Equipment (Grounded Type)
Installation (Over-voltage) Category II for transient over-voltages
AC & dc Mains supply voltage fluctuations are not to /-10% of the
rated supply voltage range.
User is responsible for the provision of an external Disconnect Means
(and Over-Current Protection) for the equipment (both ac and dc models).
Display
Alphanumeric 2 x 16 LCD digital display.
Six push-button switches (up, down, right, left, enter, exit) operable through
explosion-proof window using hand-held magnet. Viewing at 90-degree
mounting intervals.
Process fluid
and ambient
temperature
Process Fluid:
Standard temperature sensor: -55 °C to 232 °C (-67 °F to 450 °F)
High Temperature sensor: -267 °C to 454 °C (-448 °F to 850 °F)
Ambient:
Operating temperature range: -40 to 60 °C (-40 to 140 °F)
Storage temperature range: -40 to 85 °C (-40 to 185 °F)
Maximum relative humidity: 0-98%, non-condensing conditions
Maximum altitude: 2,000 meters (6,560 feet)
Pollution Degree 2 for the ambient environment
Содержание RIM20
Страница 49: ...IM P198 05 MI Issue 2 49 Run mode screens Press Exit to return to Run mode Use keys to access each item...
Страница 50: ...IM P198 05 MI Issue 2 50 4 3 Using the set up menus Run mode screens...
Страница 52: ...IM P198 05 MI Issue 2 52 4 5 Output menu...
Страница 56: ...IM P198 05 MI Issue 2 56 4 7 Alarms menu Energy EM meters only...
Страница 66: ...IM P198 05 MI Issue 2 66 4 14 Diagnostics menu...
Страница 132: ...IM P198 05 MI Issue 2 132...