IM-P198-05
MI Issue 2
107
Factory Defaults
Reset factory defaults. If you change this to Yes and press Enter,
all the factory configuration is lost and you must reconfigure the
entire program. Consult the factory before performing this process,
it is required only in very rare cases.
Config Code
Factory use only.
Test Pulse Out
Force totalizer pulse. Set to Yes and press enter to send one pulse.
Very useful to test totalizer counting equipment.
Test Scaled Freq
Enter a frequency value in order to test the scaled frequency output.
Return to 0 to stop the test.
Output Type
Factory use only.
Calibration mode
Factory use only.
A2D Ref. Resistor
Factory use only.
Pressure Cal Current
Calibration value for the electronics and pressure transducer
combination. Consult Factory for value.
Pressure 9Cs
Nine pressure coefficients unique to the pressure transducer. Use
the RIGHT ARROW to access all nine coefficients.
Press. Max psi = Based on installed sensor.
Press. Min psi
0 psi aRTD1. Press the RIGHT ARROW to access:
Ro = RTD resistance at 0 °C (1000 ohms).
A = RTD coefficient A (.0039083).
B = RTD coefficient B (-5.775e-07).
RTD1 Max Deg. F = 500
RTD1 Min Deg. F = -330
RTD2
Second RTD configuration, for special applications only.
Correction Pairs
ft3/sec (1 through 10)
%Dev. (1 through 10)
Roughness
Factory use only.
Force Recal?
Factory use only.
Min. Delta H - Energy
EM meters only
Sets the deadband for totalization to begin. Must be greater than
this number (1 default) to initiate the totalizer.
Init Displ. (sec)
Enter a value in seconds to initialize the display every xxx seconds.
Enter a value of 0 to disable initializing the display.
Содержание RIM20
Страница 49: ...IM P198 05 MI Issue 2 49 Run mode screens Press Exit to return to Run mode Use keys to access each item...
Страница 50: ...IM P198 05 MI Issue 2 50 4 3 Using the set up menus Run mode screens...
Страница 52: ...IM P198 05 MI Issue 2 52 4 5 Output menu...
Страница 56: ...IM P198 05 MI Issue 2 56 4 7 Alarms menu Energy EM meters only...
Страница 66: ...IM P198 05 MI Issue 2 66 4 14 Diagnostics menu...
Страница 132: ...IM P198 05 MI Issue 2 132...