118150-001 REV. B
Page 23 of 66
3.4.5.11 Enter User Configuration <31>
Description:
It allows users change following settings: Ramp Time and Watchdog time
out. A password must be sent in order for the firmware to allow
modification of these values. The password is ‘4343’.
Direction:
Host to supply
Syntax:
<STX><31><,><ARG><,><CS><ETX>
Where <ARG> = 4343
Response:
<STX><31><,><ARG><,><CS><ETX>
Where:
<ARG>= $ or error code.
Error Codes: 1 = receive error, 2 = unrecognized command