118150-001 REV. B
Page 64 of 66
4.15.14 Get MA monitor <61>
Description:
The host requests that the firmware report the monitored MA.
Direction:
Host to supply
Syntax:
<STX><61><,><ETX>
Response:
<STX><61><,><ARG><,><ETX>
Where:
<ARG>= 1-3 digits number in ASCII format representing un-scaled mA
value in units of micro amps.
Example:
For 0.2 mA
<STX>61,200,<ETX>