118150-001 REV. B
Page 11 of 66
3.4.3 COMMAND OVERVIEW
Command Name
<CMD>
<ARG>
RANGE
Set KV
10
1-4 ASCII
0-Max KV
Set MA
11
1-4 ASCII
0-Max mA
Request KV Set-
point
14
None
Request MA Set-
point
15
None
-
Request Status
22
None
-
Request Software
Version
23
None
-
Request Model
Number
26
None
-
Tickle Watchdog
27
None
-
Enable Watchdog
28
1-2 ASCII
1-10
Ramp Time
29
1-4 ASCII
1 - 1000
User Configuration
31
4 ASCII
-
Reset Faults
52
None
-
Get KV monitor
60
None
-
Get MA monitor
61
None
-
Get X-RAY Status
98
None
-
Turn X-RAY
ON/OFF
99
1 ASCII
0 or 1
Содержание XRB011
Страница 11: ...SPELLMAN HIGH VOLTAGE Introduction 1 Installation and Operating Manual Page1 6 118149 001 REV F 50W OPTION ...
Страница 69: ...118150 001 REV B Page 33 of 66 Figure 9 Web Page 1 Contact Information ...
Страница 74: ...118150 001 REV B Page 38 of 66 4 3 2 7 Version Information Figure 15 Version Information ...