background image

 

Feed Service Port 

 

Feed/Service Valve 

 

Feed Flow Gauge 

 

Feed Pressure 

Product water to tank 

 

Brine discharge to drain 

 

Electric Diversion valve 

 

Product Flow Meter 

 

Brine discharge pressure 

 

Brine discharge/Service Valve 

 

Brine Service port 

Electric Pressure Relief Valve 

 

Membrane pressure Gauge 

 

Electric Fresh water flush valve 

 

Manual fresh water flush valve 

The Valve and Gauge panel 

Both of the watermakers are identical and are capable of fully automatic operation or can be 
run manually.  In manual mode the system is still protected from loss of feed pressure and ex-
cess membrane pressure, which are the two main things that can cause a fault. 
 

Note that the valves (yellow handles) are shown in the off position. 

Содержание LB-20000

Страница 1: ...220 S McDowell Blvd Petaluma CA 94954 Phone 415 526 2780 Fax 415 526 2787 techsupport spectrawatermakers com www spectrawatermakers com Updated March 7 2018 LB 20 000 Containerized Watermakers with Sp...

Страница 2: ...2 Page Intentionally blank...

Страница 3: ...ation 30 Manual operation 33 Other Operating Modes 37 Auto Store 38 Spectra Connect Settings 54 Long Term Storage Procedures 39 Maintenance 41 Membrane Cleaning Procedures 46 Oil Changes 47 Tube fitti...

Страница 4: ...4 Page Intentionally blank...

Страница 5: ...Spectra Connect Quick Start Guide Run Mode Select your desired Run Mode to start mak ing water and filling your tanks See details on Run Mode options on p 37 Spectra Connect Modes and Definitions Aut...

Страница 6: ...the carrier within 24 hours of re ceiving goods LB 20k system shipping list This system is two independent LB 10000 units built into a custom fiberglass stand and installed into a 20ft ISO Shipping C...

Страница 7: ...for more detailed instructions The main valve panel for each LB 10 000 watermaker is identical and all the valves and gauges are clearly labeled The system contains both pressure transducers for the S...

Страница 8: ...elief Valve Membrane pressure Gauge Electric Fresh water flush valve Manual fresh water flush valve The Valve and Gauge panel Both of the watermakers are identical and are capable of fully automatic o...

Страница 9: ...hlorine when the unit is mak ing product water the injection pump is powered when the diversion valve is open The manufac turers operation manual is in the binder Media filters Each system has two med...

Страница 10: ...uality Note that measuring the chlorine concentration should be measured from the product tank as the chlorine injec tion point is too close to the sampling valve for ade quate mixing The black ABS Dr...

Страница 11: ...left and pressurized chlorinated water back from the storage tank The top connection is the drain that is connected to the brine discharge from both wa termakers and the back flush drain from all four...

Страница 12: ...ed Water Flow Gauge Cartridge Filter Array Flush Valve SP 20 Energy Recovery Pump Pressurized Fresh water from tank Fresh water Storage tank by others Product water Charcoal filter Fresh Wa ter Pump b...

Страница 13: ...and will self prime up to 10ft 3m The pipe runs for each of the two systems should be at least 1 1 2 up to 50 ft 15m and be increased to 2 or more f it needs to be longer Please consult our applicati...

Страница 14: ...filters so that water will drain out under the input output manifold plate built into the left side of the container Allow for drainage at the door and under the input output manifold with a gravel ca...

Страница 15: ...s frame and if you need the unit to pump water over 10 ft install a transfer tank and a delivery pump It is not recommended to use the desalinator as a prod uct water delivery pump If the product wate...

Страница 16: ...ntrol box The control system is designed to shut down when the tank switches close When tank is full both switches must be closed Note If tank switches are not used you must disable the tank switches...

Страница 17: ...as necessary If you must extend the wires beyond 50 contact the factory to en sure proper operation Connect the Tank Level Sensor cables to the appropriate terminals in the control board inside the ma...

Страница 18: ...ack on 4 Follow the screen prompts below 5 Note the Device IP address shown in and record the 10 digit numerical address on the front of this manual for future reference Note Your Spectra Connect is o...

Страница 19: ...you press on your web browser will be controlling your watermaker Caution If operating your watermaker from a computer phone or tablet you must keep the tab open while the system is in operation and t...

Страница 20: ...ing chemi cals Warning Damage will occur if the system is not purged of the storage chemicals before pressurizing the system Maintenance note Get into the habit of recording the pressures and flow rat...

Страница 21: ...media filters Turn Boost pump switch to manual Push the switch on the right up to manual start and the pump will start adjust pressure with the dial to 25psi at the media filter gauges Follow the ins...

Страница 22: ...ngers 6 Turn on the power to the system and the Spectra Connect screen will display Has the system been stored with chemicals Press Yes to start the Purge sequence The system will purge the storage ch...

Страница 23: ...ase the Boost Pressure rotate the dial on the Boost Pump Speed Control 9 Using the buttons on top of the filter housings bleed out the air in the filter housings until water is coming out 10 Check the...

Страница 24: ...case there is any residual chemicals in the membrane Carefully inspect for leaks over the entire system Shut down the sys tem and repair any leaks you find 13 After the Product Purge cycle completes t...

Страница 25: ...sed add 565grams of 65 hypochlorite then top off the tank with fresh water Make adjustments to the Stroke Rate strokes per mi nute and Stroke Length amount per stroke while the unit is running Start w...

Страница 26: ...ew filters are in place before proceeding 2 Follow the steps in Figures 1 4 below to initiate the Calibration Sequence Sensor Calibration Many of the settings on your system have been pre calibrated d...

Страница 27: ...Follow the steps below to enter the calibration se quence for the optional Tank Level Sensor s The tank needs to be full to proceed with the calibration process and you need to measure the approximate...

Страница 28: ...uring testing and is not normally required during commissioning If the product quality is not reading accurately follow calibration steps A handheld salinity meter or other reliable device is required...

Страница 29: ...ouch the Gal Liter field to enter the volume of the container used 6 Touch the Minutes field to enter the minutes it took to fill the container Only enter the minutes ex 3 min 15 sec should be entered...

Страница 30: ...he pump plungers 3 Press the Start button then select the desired operating mode 4 Runs your watermaker until the Tank Full switch closes fresh water flushes the system then goes into Auto Store mode...

Страница 31: ...the Di version Valve opens allowing water to enter the tanks and the screen image changes Verify that the system is operating according to the factory specifications detailed on p 36 See the Troubles...

Страница 32: ...s tem will enter standby mode waiting for the next run cycle Installation note If the feed tank water level is above the drain then it may be necessary to close the feed valve when the fresh water flu...

Страница 33: ...mps feed pump Pearson pump and chlorine injection pump 1 Confirm the inlet valve and the brine discharge valves are in the RUN position The Brine Discharge valve handle should point up The Feed water...

Страница 34: ...e middle of the lid to push it down while tightening the lid Note if the pump bowls do not fill per the above remove the lid and fill the bowl com pletely with water This should allow the pump s to pr...

Страница 35: ...wise to open the valve so product water will flow to the storage tank 11 Flip the switch on the control box for the Chlorine Injection so it will run manually Chlorine is not injecting if the light is...

Страница 36: ...lip the toggle switch to SERVICE 11 Allow the system to flush until the brine discharge is 1000ppm salinity about 5 minutes You can check this by holding a container under the brine discharge service...

Страница 37: ...tional user commands Additionally if power is interrupted at any stage of operation the Spectra Connect will return to Auto Fill mode ensuring that your tanks will always have water Run Low Mode You c...

Страница 38: ...pressurized fresh water source 50 psi and has a carbon filter included to remove chlorine for the flushing cy cle Note If the system runs out of water the pump s will be damaged Make sure the pressur...

Страница 39: ...tions System Storage for up to 6 months Pickling If the system is to be left unused for more than 2 weeks perform the following storage procedure The procedure introduces a chemical compound SC 1 into...

Страница 40: ...toggle switch on the main control box to Service to turn on the pump and circulate the storage chemical in the system for at least 20 minutes 6 After 20 minutes flip the service switch off Clean Up T...

Страница 41: ...f the system including the feed water supply pump Open the housings and discard old filters Clean out the housing bowls check and lubricate the o rings with silicone grease and reassemble the housings...

Страница 42: ...to each use or when the pressure drop across them increases by 5 10psi See media filter manual for detailed instructions Replace the media every 10 years or when the media filters lose effectiveness F...

Страница 43: ...ble Each time you start the watermaker open the oiler lever pointing up and allow 4 5 drips to fall Unscrew the top of the oiler to increase the drip rate Be sure to close the valve to limit the amoun...

Страница 44: ...will need to be replaced every 6 12 months based on usage and duty cycle There are test strips that should be used on a regular basis daily while learning how the system responds to local conditions t...

Страница 45: ...espond to both cleanings this is an indication of another problem with the system or that it is time to replace the membranes Contact Spectra Watermakers before removing a membrane If known bio foulin...

Страница 46: ...system for at least 20 minutes 6 After 1 hour turn the service switch off If the cleaning solution cannot be heated to 120 F 45 C then allowing the solution to soak for several hours will increase ef...

Страница 47: ...appears milky Note that if the oil appears milky it is time to change the seals as water is get ting into the crankcase from the pump head There is a dip stick at the back of the crankcase to check th...

Страница 48: ...48 Black Parker tube fittings...

Страница 49: ...49 John Guest Super Speedfit Fittings...

Страница 50: ...ate permeate flow meter Replace seals Replace Damper Piston and Seal Replace Pistons and Seals Check membrane pressure against nominal system parameters Recovery Ratio Increasing Worn Pistons Permeate...

Страница 51: ...or display system does not operate Display has gone to sleep Remote display not con nected No power to control box Touch the screen to wake it up Check display cable connections at back of display and...

Страница 52: ...e Clean membrane High Pressure Blocked brine discharge or product line Fouled membrane Re starting No signal from Rotoflow meter at startup System airlocked See remedy above for system stalled Service...

Страница 53: ...iving IP address from router or switch Connect the control board to a router or switch according to the Networking instructions Cycle power on the water maker with the network cable connected Power su...

Страница 54: ...effects on the system In some cases your watermaker will continue to function in its last known operating state The Spectra Connect has built in data logging allowing for easy access to historical op...

Страница 55: ...n sor System stalled alarms occur when the control board does not sense any product water being pro duced and shuts down to protect the pump from running dry Poor Quality Fault Disables the High Salin...

Страница 56: ...op tions Clear Statistics Resets all of the Estimated Maintenance Intervals back to 100 This feature should only be used on a brand new system Change Username password Changes the default username and...

Страница 57: ...ining in the tank and the tank switches which allow the system to turn on off automatically Boost Pressure Setup Enable alternate Boost Pressure sensors change the Low Vacuum Limit or Boost Pressure S...

Страница 58: ...ables an optional power sensor after it is installed PH ORP Enables an optional pH or ORP meter after it is installed Z Ion Enables or Disables the optional Z Ion system after it is installed If the Z...

Страница 59: ...rane endcap Check intake line for restrictions blockages or air leaks Close Pressure Relief Valve on Pump Confirm controller settings correct SERVICE PREFILTER FAULT The Service Prefilter fault is tri...

Страница 60: ...esent in flush water They must be of proper specification to be suitable There is no test for chlorine dam age except the process of elimination of other causes DIRTY OR SCALED membranes A dirty forei...

Страница 61: ...or by Pickling your membrane Keeping the prefilters clean is also im portant in preventing bio fouling If your prefilters are allowed to become a breeding ground for bacteria get smelly the contaminat...

Страница 62: ...of the detergent Run the sys tem unpressurized with pressure relief valve open with the watermaker drawing water from the bucket and discharging overboard When about half the water is gone from the bu...

Страница 63: ...n overnight These bacteria can spread throughout the watermaker and begin to grow on the membrane causing poor water quality and high feed pressures Flushing the system with fresh water after every us...

Страница 64: ...64...

Страница 65: ...65...

Отзывы: