10. When the Run Cycle completes, the system will start the Fresh Water Flush cycle.
If you stop the system (interrupting the run cycle) the system will also start a flush cy-
cle.
The system must be FRESH WATER
FLUSHED AFTER EACH USE, or serious
damage can occur.
11. After Fresh Water Flushing the sys-
tem will enter standby mode waiting for
the next run cycle.
Installation note; If the feed tank water level is above the drain then
it may be necessary to close the feed valve when the fresh water
flush cycle is completed.
To check this; confirm the feed tanks are full and do a fresh water
flush. When the flush is complete check the brine discharge and if
water is flowing it is siphoning out of the feed tank and the only way
to stop this is by closing the feed valve.