“Salinity High”
High product water salinity
Chlorine damage to mem-
branes
Defective salinity probe or
cable, cable disconnected
Check for low feed pressure
Check for leaks at high pressure
hoses
Remove and clean probe contacts.
Check calibration
Check cable connections
Clean membrane
SYMPTOMS
PROBABLE CAUSE
REMEDY
“System Stalled”
alarm is caused ty the roto-
flow not reading properly, if
no product flow the system
alarms “System Stalled”
Pressure relief valve open
Intake thru-hull closed
Airlocked system
No signal from Rotoflow
meter
Close pressure relief valve
Check thru-hull
Purge air
Check wiring, confirm roto-
flow is spinning, clean or re-
place Rotoflow meter
Check brine discharge
Clean membrane
“High Pressure”
Blocked brine discharge or
product line
Fouled membrane
“Re-starting”
No signal from Rotoflow meter
at startup.
System airlocked
See remedy above for “system
stalled”
“Service Prefilter”
Clogged filters
Loose or defective pres-
sure sensor wires
Install new filters
Check sensor wiring
If the error persists, follow
Prefilter Calibration instruc-
tions.
Troubleshooting Spectra Connect Alarms
“Can’t Connect to Water-
maker from Web Browser”
Device (phone/tablet/
computer) not connected to
same network
Router/Switch turned off
Watermaker turned off
Connecting to wrong web
address
Check the wireless network on your
mobile device or computer
If using a wired connection, confirm
you are connected to the same net-
work.
Make sure Router/switch has power.
Restart Router/Switch
Make sure watermaker is powered on
Confirm Device IP address matches
address typed into browser