21
2. Confirm there is water to the feed pumps, the pumps must
be full of water (primed) before starting or damage to the
seals will result. See boost pump manual for priming in-
structions, if required.
Start the boost pump and confirm there is pressure show-
ing on the gauges at the media filters;
Turn Boost pump switch to manual
Push the switch on the right up
to manual start and the pump
will start, adjust pressure (with the dial)
to 25psi at the media filter gauges
Follow the instructions on the media fil-
ter valves and do manual two back flush-
es on each filter prior to going to the next
step.
3. Reset the switches on the boost pump control to the
Auto Run position (left switch up and right switch in the
middle).
New System Start-Up and Testing continued...