Setup Instructions on Chlorine Injection System
The chlorine injection system is activated when the di-
version valve is directing product water to the storage
tank(s).
Priming the system
Fill the Chlorine injection tank halfway with water and
with the watermaker(s) running set both the stroke and
frequency to 100%.
Mark the chlorine injection lines so you can reconnect
them correctly. Disconnect both of the chlorine injec-
tion lines from the fittings behind the black drain pipe.
When water is coming out of the tubes reconnect to the
fittings on the product lines (be sure to connect to the
correct system). It may take up to 30 minutes to prime
the system.
With the system primed add 1/2 gallon (2 liters) of liquid
bleach (5% solution) and then top off the tank with fresh
water.
If powdered Calcium Hypochlorite is used, add
565grams of 65% hypochlorite, then top off the tank
with fresh water.
Make adjustments to the Stroke Rate (strokes per mi-
nute) and Stroke Length (amount per stroke) while the
unit is running. Start with the stroke length at 100%
and set the rate at 50% which should be about 1 stroke
every 5 seconds. The actual flow rate from the injec-
tion pump is 3 gpd (11 lpd) at 100% Stroke and 100%
Frequency.
These settings should result in a chlorination level of
about 1 ppm. Test with the test strips at the storage
tank after the system has run for at least an hour, and
adjust as required.
To increase the PPM level increase the stroke frequency.
Check the chlorine level in the tanks daily for the first week to confirm it is working at
the rate expected. The concentrated solution should be replaced every 10 days. Ad-
just the batch size of the concentrate tank according to anticipated usage.
The manufacturers manual for the chlorine injector included in this binder.
New System Start-Up and Testing continued...
Chlorine lines
Содержание LB-20000
Страница 2: ...2 Page Intentionally blank...
Страница 4: ...4 Page Intentionally blank...
Страница 48: ...48 Black Parker tube fittings...
Страница 49: ...49 John Guest Super Speedfit Fittings...
Страница 64: ...64...
Страница 65: ...65...