41
MAINTENANCE
General
Periodically inspect the entire system for leakage and chafe on the tubing and hoses.
Repair any leaks you find as soon as practical. Some salt crystal formation around the
Spectra-Pearson Pump blocks is normal. Wipe down any salt encrusted areas with a
damp cloth.
Pre-filters
Service the pre-filters as soon as the Boost Pressure
drops 10psi from when new filters were installed.
To service the filters shut off the system including
the feed water supply pump. Open the housings and
discard old filters. Clean out the housing bowls,
check and lubricate the o-rings with silicone grease
and reassemble the housings with new 5 micron filter
elements. Leave dry until next startup.
Use only Spectra approved pleated polyester filters
or you may void your warranty.
Boost Pump maintenance
Routinely inspect the basket strainers integrated
with the Boost Pumps. If these strainers become
clogged, the pumps can be damaged.
Inspect the pumps daily for leaks and address
leaks immediately.
See the boost pump manufacturers manual for de-
tained instructions.