80
Southwestern Industries, Inc.
TRAK
2
OP
M11 Installation, Maintenance, Service, & Part List Manual
Note changed fuse size on 7/2015 from 8 amps to 10 amps. Use this value
moving forward.
1 fuse (4 amps) that controls power of the worklight, electrical cabinet fans,
spindle fan and labeled F16 (23152-4 Time Delay).
1 fuse (4 amps) that controls power to auxiliary 115 volt outlet labeled F10
(23152-4 Time Delay). This 115 volt auxiliary outlet should only be used to run
an indexer or low current devices like a light or laptop.
1 fuse (1 amp) for the 24 volts that controls NC Ready labeled F15 (23152-1
1 amp Time Delay).
1 on the lube pump (5 amps Fast Acting).
440 Volt Machines
2 on the computer module (see section 5.3).
o
F1
–
coolant pump, lube pump
–
5 amps (21824-5 Time Delay).
Note changed to 5 amp from 4 amp on 7/2015.
o
F2
–
computer module power supply
–
4 amps (21824-4 Time Delay).
3 next to the on/off switch are for the 3 phase 440 volt power in (15 amp) and
labeled F4, F5 and F6 (23152-16 Time Delay).
3 fuses (8 amps) for the spindle inverter labeled F7, F8 and F9 (23152-8 Time
Delay).
2 fuses (16 amps) for the servo drives labeled F20 and F21 (23152-16 Time
Delay).
Note changed fuse type on 7/2015 from 15 amps to 16 amps each.
2 fuses (12 amps) for the incoming power to transformer labeled F18 and F19
(23152-12 Time Delay).
1 fuse (10 amp) that controls power out of the transformer to the computer
module labeled F24 (23152-10 Time Delay).
.
Note changed fuse size on 7/2015 from 8 amps to 10 amps (Time Delay). Use
this value moving forward.
1 fuse (4 amps) that controls power of the work light, electrical cabinet fans,
spindle fan and labeled F23 (23152-4 Time Delay).
.
1 fuse (4 amps) that controls power to auxiliary 115 volt outlet labeled F10
(23152-4 Time Delay). This 115 volt auxiliary outlet should only be used to run
an indexer or low current devices like a light or laptop.
1 fuse (1 amp) for the 24 volts that controls NC Ready labeled F22 (23152-1
Time Delay).
1 on the lube pump (5 amps Fast Acting).
To check fuses:
Use a Volt/Ohmmeter; select “OHM”.
Remove the fuse completely from the holder.
Place a lead of the meter on each end of the fuse.
A good fuse reads 0 (zero) or close to it.
A bad fuse reads Open or Infinity.
Содержание TRAK 2OP M11
Страница 6: ...3 Southwestern Industries Inc TRAK 2 OP M11 Installation Maintenance Service Part List Manual...
Страница 7: ...4 Southwestern Industries Inc TRAK 2 OP M11 Installation Maintenance Service Part List Manual...
Страница 8: ...5 Southwestern Industries Inc TRAK 2 OP M11 Installation Maintenance Service Part List Manual...
Страница 12: ...9 Southwestern Industries Inc TRAK 2 OP M11 Installation Maintenance Service Part List Manual...
Страница 71: ...68 Southwestern Industries Inc TRAK 2 OP M11 Installation Maintenance Service Part List Manual...