127
Southwestern Industries, Inc.
TRAK
2
OP
M11 Installation, Maintenance, Service, & Part List Manual
6.10 Spindle Cartridge Replacement
Please refer to assembly drawing 27500-1 found at the back of this manual.
1.
Remove the left and right side sheet metal covers
2.
Remove the unclamp button panel.
3.
Jog the Z-axis downward toward the table so you have access to the unclamp panel and the 6
bolts that hold the spindle cartridge in place.
4.
Press the E stop on the control.
5.
Remove the clamp/unclamp bracket assembly (A), air line (B), oil line (C) and the actuator plate
(D). Reference figure 6.10
Figure 6.10
6.
Loosen the 2 clamp screws on the motor coupler.
7.
Remove 5 of the 6 bolts that holds the spindle cartridge up inside of the head. Loosen the 6 bolt
as well.
8.
Jog the Z-axis downward toward the table and place the spindle nose on top of a block of wood.
9.
Remove the last bolt and now move the head up with the handwheel to expose the spindle
cartridge.
10.
Install the new spindle cartridge in reverse order. It is recommended to perform tightening of
the screws crosswise in order to prevent any distortion of the hub. These bolts are to be
tightened to 8 ft-lbs.
11.
It is very important to set the clamp and unclamp switches correctly upon installation.
12.
Enter service code 510 to set spindle orientation and follow the on-screen instructions.
Содержание TRAK 2OP M11
Страница 6: ...3 Southwestern Industries Inc TRAK 2 OP M11 Installation Maintenance Service Part List Manual...
Страница 7: ...4 Southwestern Industries Inc TRAK 2 OP M11 Installation Maintenance Service Part List Manual...
Страница 8: ...5 Southwestern Industries Inc TRAK 2 OP M11 Installation Maintenance Service Part List Manual...
Страница 12: ...9 Southwestern Industries Inc TRAK 2 OP M11 Installation Maintenance Service Part List Manual...
Страница 71: ...68 Southwestern Industries Inc TRAK 2 OP M11 Installation Maintenance Service Part List Manual...