PERIODIC MAINTENANCE
To guarantee optimal system operation and to maintain its performance over time, plan on
conducting an operation test on each Control Unit (UG) once a year.
9
MAINTENANCE
Malfunction Probable
cause Solution
In “Configuration” mode
:
The LED for the Control Unit
(UG) blinks continuously.
Faulty
wiring.
No communication between
the Control Unit (UG) and the
1
st
sensor.
Disconnected
cable.
The last UT/UR is configured
in "UR"
Check the wiring on the
Control Units (UG) and on
the Termination / Link Units
(UT/UR).
The configuration switch for
the detector cable is not in
the right position.
(A or B: see §5.1)
Connect to the web server,
View tab (§11.4) to identify
the cut.
Set the last UT/UR is "UT"
(see §5.2)
In “Detection” mode
:
The LED for the Control Unit
(UG) blinks.
Disconnected
cable
No zones are configured
Connect to the web server,
View tab (§11.4) to identify
the cut.
Setting the detection zones
(see §6)
Green LED blinking
Power Supply fault.
(<10.5V)
Check the power supply.
10
PARAMETER BY DEFAULT
Title Value
Notes
IP Address
192.168.105.202
To write the url of the web browser
Network mask
255.255.255.0
Check compatibility with the network
settings of the host
Login “admin”
Connection parameter in ASCII
(case sensitive)
Password for login
"admin"
(
4 spaces)
read-and-write access
Login
“user”
Connection parameter in ASCII
(case sensitive)
Password for login "user" “0000”
read only access
Sensitivity cable
8
From 1 to 16
Event before alarm
1
From 1 to 10