- 41 -
SORHEA
G-WALL
6
IMPLEMENTATION
1) Move the switch to “ZONE 1” or “ZONE 2” to enter configuration mode for the Control Unit
(UG) and to configure the cable selection (zone 1 or zone 2).
The buzzer will beep twice to confirm entry into configuration mode.
The red LED starts blinking.
2) The buzzer beeps once and the red LED turns off. Configuration is finished.
If after 2 minutes the buzzer still does not beep and the red LED is still blinking, refer to §9
MAINTENANCE.
3) Please refer to chapter §
Erreur ! Source du renvoi introuvable.
detection settings.
4) Repeat steps 1) to 3) for the second cable.
5) Move the switch to “DETECT”.
The buzzer will beeps twice to confirm entry into detection mode.
6) Move switch 1 on “ON” to activate the buzzer
7) Trigger alarms on the fence to test the alarm triggering on zone 1 and 2. The red led is lit and
the buzzer beeps when there is an alarm.