![background image](http://html.mh-extra.com/html/sony/dvcam-dsr-50/dvcam-dsr-50_service-manual_422880198.webp)
5-68
21. E-E Blanking Level Adjustment (VD-28 Board)
Mode
E-E
Signal
Color bar (NTSC: with 7.5% setup)
(CAMERA input) (Note)
Measurement Point
COMPONENT OUTPUT Y terminal
(75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
E
Adjustment Address
CC
Specified Value
A = 0 ± 3 mV
Note1:
Set “CAMERA” mode with INPUT SELECT switch
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: E, address: CC, change the data and adjust the
blanking level (A) to the specified value.
3) Press the PAUSE button of the adjustment remote commander.
4) Select page: 0, address: 01, and set data: 00.
A
magnified
magnified
A
Fig. 5-3-27
For PAL model
For NTSC model